Toshiba RAC-08EW-E Service Manual page 20

Room air-conditioner portable type
Table of Contents

Advertisement

(B) Water Leaks
Causes:
(1) There is a moisture generating source in the room.
Note that, even if a ventilation fan is not in
operation, if it is open to the outside, the con-
dition is same as the one in operation.
(2) Air volume is remarkably reduced.
Air filter is blocked, resulting in the reduction
of air volume.
Low fan operation causes the lowering of run-
ning voltage, resulting in the reduction of air
volume.
If the voltage is in the range of 198 – 264V, it
is normal.
Installation condition of the air
conditioner is defective.
Normal
Dew condensation on the
external body.
– 20 –
Water stays here.
(3) Window has been kept open while raining, and
after that, cooling operation is started.
On rainy days, relative humidity may become
as high as 90% or higher. If doors or windows
are open to the outside, close them.
(4) When a man goes in and out between a room
with high humidity and one with low humidity. Or,
in case there is no door between such rooms.
Even if there is no moisture generating source
in the room where the air conditioner is in-
stalled, in case people go in from and out to a
room with high humidity frequently, or in case
there is no door between the rooms, the situ-
ation becomes the same.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents