5. ELECTRICAL ADJUSTMENT

5-1. Table for Servicing Tools
Ref. No.
Name
J-1
Color viewer 5,100 K
Siemens star chart
J-2
Calibration software
J-3
Chart for color adjustment
J-4
Extension cord
J-5
Note: J-1 color viewer is 100 - 110 VAC only.
J-1
J-3
J-5
5-2. Equipment
1. Oscilloscope
2. Digital voltmeter
3. PC (IBM R -compatible PC, Pentium processor, Window
98 or Me)
4. AC adaptor
5-3. Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.1 V (A) Voltage Adjustment
3. 12.4 V (L) Voltage Adjustment
4. Hall Element Adjustment
5. AWB Adjustment
Part code
VJ8-0007
VJ8-0178
VJ8-0155
VJ8-0176
J-2
J-4
6. Lens Adjustment
7. CCD Defect Detect Adjustment
8. LCD Panel Adjustment
8-1. LCD H AFC Adjustment
8-2. LCD RGB Offset Adjustment
8-3. LCD Gain Adjustment
8-4. LCD Blue Brightness Adjustment
8-5. LCD Red Brightness Adjustment
Note: If the lens, CCD and board in item 5-7, it is necessary
to adjust again. Adjustments should be carried out in
sequence. For 7, carry out adjustment after sufficient
charging has taken place.
5-4. Setup
1. System requirements
Windows 98 or Me
IBM R -compatible PC with Pentium processor
CD-ROM drive
3.5-inch high-density diskette drive
USB port, 40 MB RAM
Monitor which allows full-color or high-color display
IEEE1394 port (when carrying out IEEE1394 operation com-
pliance checks)
2. Installing calibration software
1. Insert the calibration software installation diskette into your
diskette drive.
2. Open the explorer.
3. Copy the DscCal_162 folder on the floppy disk in the FD
drive to a folder on the hard disk.
3. Installing USB driver
Install the USB drive which are included in the computer con-
nection kit.
4. Installing IEEE1394 driver (when carrying out IEEE1394
operation compliance checks)
Install the B's CLip which are included in the computer con-
nection kit.
5. Color Viewer
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure.
6. Computer screen during adjustment
Calibration
Upload
AWB
Firmware
Focus
Image
UV Matrix
Cal Mode
Initialize
OK
EVF
Cal Data
LCD Type
OK
USB strage
VID
Get
PID
Set
MAC address
Get
– 24 –
LCD
R Bright
B Bright
RGB Offset
Gain
Tint
Phase
H AFC
Test
Set
Serial
Set
Set
Rev.
Set
Set
VCOMDC
VCOMPP
Setting