A-1
TECHNICAL SPECIFICATIONS – COOL ARC
Product No. / Model
Input
Current Draw @ 60Hz Input
Current Draw @ 50Hz Input
Maximum Operating Pressure and Flow Rate
(Open Flow, Without Welding Torch Restriction)
Typical Operating Pressure and Flow Rate
(With Welding Torch Restriction)
Reservoir Size
Recommended Coolant
Shipping
Weight
Reservoir
Full (Water)
L
W
Dimensions
H (Top Face)
H Top Handle)
EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT
O

INSTALLATION

K2187-1 ( COOL ARC® 40 230V International)
Via Continental European (SCHUKO)- PRONG PLUG
For Use Above Freezing: Use Clean tap, distilled or de-ionized water.
For Use Below Freezing: Use 50% water and 50% pure ethylene glycol
DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.
These coolants will damage the pump and block the small internal passageways of the
heat exchanger, affecting cooling performance. To acquire the proper coolant contact
a local welding distributor.
DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain
oil-based substances, which attack the plastic components of the cooler. Once added
to the cooler, these substances are virtually impossible to purge from the water lines
and heat exchanger.
ON
OFF
OFF
COOL ARC® 40
220-240VAC 50/60 Hz 1 Phase
1.3-1.7 Amps
2.0-2.4 Amps
60 psi (414 kPa) (4.14 bar)Max.
1.66 gal/min. (6.28 liter/min) Max.
53-57 psi (365-393 kPa)
.45-.60 gal/min. (1.7-2.3 liter/min)
2.0 ga. (7.6 liters)
(reagent or industrial grade) mixture.
46.5 lbs. (21.1 kg)
61.2 lbs. (27.8 kg)
9.03 in. (229.4mm)
9.10 in. (231.1mm)
31.99 in. (812.6mm)
34.26 in. (870.2mm)
A-1