COOL ARC
®
55 & COOL ARC
Product No. / Model
Input
Current Draw @ 60Hz Input
Maximum Operating Pressure and Flow Rate
(Open Flow, Without Welding Torch Restriction)
Typical Operating Pressure and Flow Rate
(With Welding Torch Restriction)
Reservoir Size
Recommended Coolant
Shipping
Weight
Reservoir
Full (Water)
L
Dimensions
W
H (Top Face)
EMC Classification
Temperature Range
Cooling Power
*
Cooling Power is measured at a 1 L/min. flow rate with a 40°C coolant temperature rise in a 25°C (77ºF) environment.
EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT
I
O
®
55 ALUMINUM WATER COOLER
TECHNICAL SPECIFICATIONS – COOL ARC
For Use Above Freezing: Clean tap, distilled or de-ionized
For Use Below Freezing: 50% water and 50% pure ethylene
DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers. These coolants will
damage the pump and block the small internal passageways of the heat exchanger, affecting cooling
performance. To acquire the proper coolant contact a local welding distributor.
DO NOT USE: Non-Lincoln branded industry coolants. These coolants may contain oil-based substances,
which attack the plastic components of the cooler. Once added to the cooler, these substances are
virtually impossible to purge from the water lines and heat exchanger.
ON
OFF
OFF
K3086-1 ( COOL ARC
VIA 3-Prong Plug NEMA Type 5-15P
115VAC 60 Hz 1 Phase
3.8 Amps
60 psi (414 kPa) (4.14 bar) Max.
1.66 gal/min. (6.28 liter/min) Max.
53-57 psi (365-393 kPa)
.45-.60 gal/min. (1.7-2.3 liter/min)
2.375 gal. (9 liters)
water.
glycol (reagent or industrial grade)
mixture.
62.6 lbs. (28.4 kg)
82.3 lbs. (37.3 kg)
26.5 in. (673.1mm)
13.9 in. (353.0mm)
11.5 in. (292.1mm)
Category 1
14°F to 104°F (-10°C to 40°C)
1.33 kW (4540 BTU/hr.) @ 1 L/min.
COOLANT
OUT
COOLANT
IN
A-1

INSTALLATION

55
®
®
55 )
A Magnum
®
PRO AL coolant may be
used in aluminum push-pull systems
where high frequency is NOT used.
Lincoln Electric Low Conductivity Coolant
may be used in MIG and TIG systems
(but NOT aluminum push-pull) where
high frequency may be present.
*