Door Removal And Installation - Napoleon XIR4-1N Installation And Operating Instructions Manual

Table of Contents

Advertisement

12
4.2

DOOR REMOVAL AND INSTALLATION

EN
THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO
FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR
OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR
SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.
BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO
The optional front, if installed, must be
removed to allow the glass door to be
opened or closed.
The glass door is secured to the top front
edge of the fi rebox with two latches. Pull the
handles of the latches forward, then lift the
latches out from the door frame to release
the top of the door. Next, pivot the door
forward until the top edge clears the front of
the appliance. Carefully grip the sides of the
door lifting it out from the retainer along the
bottom of the door.
NOTE: The protective wrap on plated
parts is best removed when the assembly is at room temperature but this can be improved if the
assembly is warmed, using a hair dryer or similar heat source.
W415-1194 / 03.04.13
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
WARNING
!
75.1
HANDLES