Lincoln Dual Technology Finisher 1921 Service Manual page 14

1920 series dual technology finisher 208vac 60 hz. 3 phase & 240vac 60 hz. 3 phase
Table of Contents

Advertisement

voltage (120/240) and frequency (50Hz./60Hz.). After the new control is installed, the
control will need to be initialized. To initialize the new control, press and hold the two center
buttons on the front control panel. After the oven starts, release the buttons, the control is
now initialized. Reassemble in reverse order and check system operation.
14
DTF – 1920 Series Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

1922

Table of Contents