Philips DELLP1230 Service Manual page 58

22" auto scan colour monitor
Table of Contents

Advertisement

58
DELL P1230 M25P
Go to cover page
3.3.3
3.3.4
3.4
3.5
3.6
.
3.7
Requirement for low emission
TYPE
OEM
2003-12-19
C.C.Liao
GENERAL PRODUCT SPECIFICATION(Continued)
Horizontal scanning
Sync polarity
Scanning frequency
Retrace time
Vertical scanning
Sync polarity
Scanning frequency
Power input connection
Power cord length
Power cord type
Video amplifiers
Rise time/Fall time
(Excluding rise/fall time due to test pattern & test probe)
Overshoot/undershoot
Black level shift
Sag
Degaussing
An automatic degaussing circuit is provided and required no intervention
The degaussing is activated at the time of switch-on and power saving
wake up or switch-on again after switched-off for longer than 30 minutes.
Manual degaussing is provided to eliminate any color impurity.
(1) Electro static potential : < +/- 0.5 KV
(2) Alternating Elec. field
ELF 5 -
2 Khz
VLF 2 - 400 Khz
(3) Magnetic field
ELF 5 -
2 Khz
VLF 2 - 400 Khz
22" CMTR-M25P-Dell-P1230
: 6L3P10/76
: Dell P1230 130KHz
2003-12-19
: Positive or Negative
130
: 30 -
KHz
: 1.6 sec (typical)
: Positive or Negative
: 50 - 160 Hz
: 1.8 M
: 3 leads detachable power cord with
Protective earth plug.
: 4.0 / 4.0 ns
: Max.
28%
: Max.
3%
: Max.
5%
:
10.0 V/M
:
1.0 V/M
:
200 nT
:
25 nT
8639 000 15121
590
31
14