Item number
Display
10
HUMID DETECT
11
TOP END BOTH DETECT
12
TAPE TOP ERROR
13
TAPE END ERROR
14
FAN MOTOR ERROR
20
CC TIME OVER
21
SHIFT TIME OVER
22
POSITION BOTH DETECT
23
THREAD BOTH DETECT
93
DR IF ERROR
97
NVRAM CHECK SUM ERROR
FF
SV UNDEFINE ERROR
A0
SY UNDEFINE ERROR
A2
SY1-SY2 DPRAM ERROR
A5
SY-FC DPRAM ERROR
A8
SY NVRAM CHECK SUM ERROR
B3
XXX PLDX INITIAL ERROR
B8
SY1-SY2 INTERFACE ERROR
B9
SY-SV INTERFACE ERROR
BA
SY-EQ INTERFACE ERROR
BB
SY-FC INTERFACE ERROR
BC
SY-50PIN INTERFACE ERROR
BD
SY-CP MISMATCH ERROR

Warning Messages

When one of the problems described below is detected, a
warning mark is displayed in the upper left corner of the
display. Operation can continue even when the mark is
flashing.
If you press the SFT button (see page 21) and the DIAG
button (see page 19) when the mark is flashing, an
information display appears, showing a warning message.
144
Error Messages/Warning Messages/Condition Messages
Meaning
Condensation was detected.
The tape beginning and tape end were detected at the same time.
A tape beginning sensor fault was detected.
A tape end sensor fault was detected.
A cooling fan motor operation fault was detected.
A fault was detected in a cassette compartment raising or lowering
operation.
A fault was detected movement of the reel table to adjust for
cassette size.
The reel table was detected in the L cassette position and S
cassette position at the same time.
The threading end and unthreading end were detected at the same
time.
A communications error between the SV CPU (board SS-95) and
drum CPU (board DR-508) was detected.
An operation fault was detected in the servo system NV-RAM
(board DR-508).
Undefined SV error was detected.
Undefined SY error was detected.
A DPRAM (board SS-95) operation fault between SYS1 and SYS2
was detected.
A DPRAM (board FC-91) operation fault between SYS1 and FC
was detected.
A SYS NVRAM (board SS-95) operation fault was detected.
An initialization error in the PLD was detected.
Note
The description of "XXX" at the beginning of the message and of
"X" immediately after the "PLD" depends on the PLD where the
error was detected.
Display example: SYS PLD1 INITIAL ERROR
A SYS CPU communications fault was detected.
An SV CPU communications fault was detected.
An EQ CPU communications fault was detected.
An FC CPU communications fault was detected.
A communications fault with the 50-pin CPU was detected.
A fault was detected in the pairing of the main unit and the lower
control panel. This appears when the lower control panel of another
unit is connected to this unit, for example.
Note
The warning messages can be viewed in any menu except
the CUE or SET UP menu.