9. Cooling Water System
Measuring clearance between impeller and pump body.
Measuring clearance between impeller and pump body
bracket.
Clearance between impeller
and body
Clearance between impeller
and plate
mm
Standard
Limit
0.3-1.1
1.5
15
-
152
Thickness gauge
Straightedge
Thickness gauge