Troubleshooting
Check procedure
4.1 Machine is not working (no function)
4 Press On/Off button to perform
automatic self test - continued
4.2 Backlighted coffee button blinks at irregular
5.1 No coffee outlet
5 Check coffee temperature while
preparing a coffee (see page 29)
5.2 Temperature is too low (less than 83°C)
5.3 Temperature is too high (more than 89°C)
6.1 Leakage at extraction system
6.2 Leakage at tubes connection
6 Check for leaks and check flow
rate (see pages 26, 27 and 28)
6.3 Flow rate out of range
7 Descaling process (if needed)
7.1 Machine scaled
8 Final cleaning (see page 30)
Service Manual EF 470 / EF 471
Symptoms
- continued
intervals
Action / repair work
YES - g) Check if electrical wires are functional
NO - Go to point 4.2
YES - Check if thermoblock heating element is func-
tional
NO - Self test ok. Go to point 5
YES - a) Water circuit is empty
YES - b) Pyramid plate is clogged
YES - c) Machine is blocked by scale
NO - Go to point 5.2
YES - Descale the machine (see page 24)
NO - Go to point 5.3
YES - Change NTC
NO - Go to point 6
YES - Replace CBU
NO - Go to point 6.2
YES - Replace defective tube and seal
NO - Go to point 6.3
YES - Machine is scaled
NO - No trouble found during the check procedure.
YES - Descale machine (see page 24)
NO - Go to point 8
End of check procedure
1 4
Further action / repair work
YES - Replace electronic mainboard
NO - Replace defective(s) wire(s)
YES - Replace NTC
NO - Replace thermoblock
YES - Fill water circuit (see page 9)
NO - Go to point b)
YES - Replace CBU
NO - Go to point c)
YES - Descale machine (see page 24)
YES - Descale machine (see page 24)
NO - Replace pump
Contact Nespresso Technical Correspondant for
further details in order to take decision.