All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

WALL MOUNT LINER INSERT
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L108 1213A
DUCTWORK
Page 1
U L
C
US
R

Advertisement

loading

Summary of Contents for VentAHood VP526

  • Page 1: Installation Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 Ducting Do’s and Don’ts General Requirements • Observe local codes regarding special duct requirements and placement of duct against combustibles. • Using Vent-A-Hood transitions (back page) will ensure proper efficiency. • Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. • Where possible, seal joints with duct tape. • The hood must be ducted to the outdoors without restrictions. Blower Requirements • The single blower unit (B100) requires 6”...
  • Page 3: Installation Details

    Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard liners only. Custom liners may require additional specification consideration. 2) When installing a SLD wall mount liner (19 1/4” deep), it is recommended that the bottom edge of the liner be located no more than 24”...
  • Page 4 Installation Details Continued Connection Diagram (28 3/8”- 40 3/8” Widths) Connection Diagram (28 3/8”- 52 3/8” Widths) 1 ¾” 5 ¼” 1 ⁄ ” 5 ½” 5 ¼” Wall Side Wall Side Vent Vent Holes Hole 1 ¾” Electrical 8” Outlet Electrical 6”...
  • Page 5 Installation Details Continued 7) Install an appropriate 1/2” UL listed electrical wire clamp through each motor box electrical opening on top of the liner. Install electrical wiring from the service panel to the liner location for each motor box. Consult the connection diagrams (on previous page) for further details on electrical placement.
  • Page 6 3 ¼” 7” 13” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL MODEL VP526 6” Round VP554 10” Round VP555 12” Round VP538 6” x 8 ½“ VP527 7” Round VP560 3 ¼” x 10”...

This manual is also suitable for:

Vp554Vp527Vp528Vp555Vp539Vp540 ... Show all