VentAHood DAH18 Installation Instructions Manual

Wall mount range hood

Advertisement

Quick Links

DAH18/PWVH18/XRH18/XRXH18 WBAR warming light bar is available on selected models. X in part
number indicates 27" depth.
DAH18
5 ¼"
1 ⁄ "
Vent
Hole
6" Outlet
3 ¼"
300 CFM B100 Single Blower
(Top View)
7 ⁄ "
5 ½"
Wall Side
5 ¼"
8" Outlet
900 CFM B200 Dual & B100 Single Blower
(Top View)
11"
5 ½"
1 ¾"
5 ¼"
8" Outlet
Electrical (2)
1200 CFM Double B200 Dual Blowers
(Top View)
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
* Add 2.5 amp for each warming light. Lighting: (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung
blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung
®
efficiently than other than other filtration systems. When comparing the Magic Lung
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
WALL MOUNT RANGE HOOD SPECIFICATIONS
Connection Diagrams (30" - 48" Widths)
1 ¾"
Wall Side
Electrical
Centerline
of Hood
Connection Diagram (42" - 60" Widths)
7 ⁄ "
1 ¾"
1 ⁄ "
Vent
Holes
Electrical (2)
6" Outlet
Centerline
of Hood
Connection Diagram (48" - 66" Widths)
11"
5 ½"
Wall Side
Vent
Holes
8" Outlet
Centerline
of Hood
Electrical/Mechanical Specifications For Blower Units
Volts
Amps*
Hz
115
3.5
60
115
5.5
60
115
8.0
60
115
10.0
60
with other blower units made by other manufacturers, use the "Equivalent CFM".
®
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1015
PWVH18
Wall Side
1 ¾"
Electrical
600 CFM B200 Dual Blower
(Top View)
10" Round
17 ½"
8" Round
2"
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
12" Round
16 ½"
8" Round
3"
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
CFM
Equivalent CFM •
RPM
SP@0.0"
1550
300
450
1550
600
900
1550
900
1350
1550
1200
1800
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
®
XRH18/XRXH18
5 ½"
5 ¼"
Vent
Holes
8" Outlet
Centerline
of Hood
10" Round
8" Round
6" Round
12" Round
8" Round
8" Round
CFM
CFM
CFM
SP@0.1"
SP@0.2"
SP@0.3"
273
245
225
531
480
430
804
725
655
1062
960
860
Recommended
Mounting Height*
*Recommended mounting
height is for optimum
performance.
10" OR 12"
Round
VP562/VP563
transition
centers outlet
over top of hood
Minimum Round
Sones
#
Duct Size
6" (28 in.
)
5.4
2
8" (50 in.
)
6.5
2
VP562: 10" (79 in.
)
6.3
2
VP563: 12" (113 in.
)
6.6
2
U L
C
US
R

Advertisement

loading

Summary of Contents for VentAHood DAH18

  • Page 1 WALL MOUNT RANGE HOOD SPECIFICATIONS DAH18/PWVH18/XRH18/XRXH18 WBAR warming light bar is available on selected models. X in part number indicates 27" depth. DAH18 PWVH18 XRH18/XRXH18 Connection Diagrams (30” - 48” Widths) Recommended Mounting Height* 1 ¾” 5 ¼” 1 ⁄ ”...
  • Page 2: Warning - To Reduce The Risk Of Fire, Electric Shock, Or Injury To Persons, Observe The Following

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 3 Ducting Do’s and Don’ts General Requirements • Observe local codes regarding special duct requirements and placement of duct against combustibles. • Using Vent-A-Hood transitions (back page) will ensure proper efficiency. • Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. • Where possible, seal joints with duct tape. • The hood must be ducted to the outdoors without restrictions. Blower Requirements • The single blower unit (B100) requires 6”...
  • Page 4 Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing a wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30"...
  • Page 5 Installation Details Continued Connection Diagrams (30”- 48” Widths) Connection Diagrams (30”- 54” Widths) 1 ¾” 5 ¼” 1 ⁄ ” 5 ½” 5 ¼” Wall Side Wall Side Vent Vent Holes Hole 1 ¾” Electrical 8” Outlet Electrical 6” Outlet Centerline 3 ¼”...
  • Page 6 Installation Details Continued 8) Install an appropriate 1/2" UL listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (on previous page) for further details on electrical placement.
  • Page 7 Installation Details Continued 14) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 15. Method 1: Place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the inside the collar(s) of the exhaust outlet(s). Use duct tape to seal joints. Lift the hood up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection(s) between the elbow(s) and the duct(s) in the wall.
  • Page 8 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 ⁄ ” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 3 ¼” 7” 13” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...
  • Page 9 Back Vent Applications (Page 1 of 4) Back Vent K250 B100 B200 B300 B400 Hood Model/Hood Style Diagram (3-1/4” x 10”) (6” Round) (8” Round) (8” Round & 6” Round) (Two 8” Round) K-Series Under Cabinet Hood and Liner Insert Standard 6”...
  • Page 10 Elbow and Transition Heights VP513: 6” Round - 8 1/2” Tall VP561: 8” Round to 6” x 8 1/2” VP559: 3 1/4” x 10” - 4 1/4” Tall When Fully Adjusted to 90 Degrees Rectangular - 7” Tall VP515: 8” Round - 10 3/4” Tall When Fully Adjusted to 90 Degrees Diagram A - Direct Back Vent Diagram B - Off the Top...
  • Page 11 Back Vent Applications (Page 2 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP559: 3 1/4”...
  • Page 12 Back Vent Applications (Page 3 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP513: 6”...
  • Page 13 Back Vent Applications (Page 4 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP513: 6”...