Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer
INSTALLATION INSTRUCTIONS
SLH6-K UNDER CABINET HOOD
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction. Switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and local code authorities.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L114A 0808A
DUCTWORK
Page 1
U L
C
US
R

Advertisement

loading
Need help?

Need help?

Do you have a question about the SLH6-K and is the answer not in the manual?

Questions and answers

Summary of Contents for VentAHood SLH6-K

  • Page 1 Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS SLH6-K UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 Ducting Do’s and Don’ts NEVER restrict the duct size. The K250 blower unit requires 7” round duct or equivalent (32.5 square inches). Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Blower Duct Size Sq. Inch Area K250 3 1/4” x 10” rectangular or equivalent 32.5”...
  • Page 3: Installation Details

    1) Read all instructions thoroughly before beginning installation. 2) When installing the SLH6-K under cabinet hood, it is recommended that the bottom edge of the hood be located no more than 21” - 24” from the cooking surface. Exceeding recommended mounting height may compromise performance.
  • Page 4 Installation Details Continued 6) Remove the hood from its packaging and place on the floor or countertop in front of the cabinet where it will hang. Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 7) Determine whether the electrical wire will enter from the top or the back of the hood.
  • Page 5 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 �⁄�” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 7” 13” 3 ¼” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...