JCH/B1 Series Equipped with LED lighting. Not available with heat lamps. Shown with optional duct
cover (sold separately). Optional duct covers available in standard and custom sizes.
5 ¼"
1 ⁄ "
Vent
Hole
Electrical
6" Outlet
3 ¼"
B100 Single Blower
(Top View)
12 ⁄ "
1 ¾"
10" Outlet
Centered On
Hood Top
900 CFM B200 Dual & B100 Single Blower
(Top View)
16 ½"
7"
1 ¾"
12" Outlet
Centered On
Top Of Hood
1200 CFM Double B200 Dual Blowers
(Top View)
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Hoods are available with LED lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66").
• Because the Magic Lung
blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung
®
efficiently than other than other filtration systems. When comparing the Magic Lung
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
OPTIONAL
DUCT
COVER
Connection Diagrams (36" - 48" Widths)
1 ¾"
Wall Side
Centerline
of Hood
(Front View)
Connection Diagram (48" - 60" Widths)
9 ⁄ "
Wall Side
Electrical (2)
Centerline
Of Hood
Connection Diagram (54" - 66" Widths)
1 ¾"
5 ½"
Wall Side
Electrical (2)
Centerline
Of Hood
Electrical/Mechanical Specifications For Blower Units
Volts
Amps
Hz
115
2.5
60
115
4.0
60
115
6.0
60
115
7.5
60
with other blower units made by other manufacturers, use the "Equivalent CFM".
®
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0715A
DESIGNER SERIES WALL MOUNT RANGE HOOD
Wall Side
1 ¾"
Electrical
VP562 Standard Transition
Installed (Front View)
VP563 Standard Transition
Installed (Front View)
CFM
Equivalent CFM •
RPM
SP@0.0"
1550
300
450
1550
600
900
1550
900
1350
1550
1200
1800
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
®
5 ½"
5 ¼"
Vent
Holes
8" Outlet
Centerline
of Hood
B200 Dual Blower
(Top View)
10" Round
8" Round
2"
VP562 Standard Transition
12" Round
16 ½"
8" Round
3"
VP563 Standard Transition
CFM
CFM
CFM
SP@0.1"
SP@0.2"
SP@0.3"
273
245
225
531
480
430
804
725
655
1062
960
860
Recommended
Mounting Height
30"
36"
*Recommended mounting
height is for optimum
performance.
(Front View)
10" Round
17 ½"
8" Round
6" Round
Included
12" Round
8" Round
8" Round
Included
Minimum Round
Sones
#
Duct Size
6" (28 in.
)
5.4
2
8" (50 in.
)
6.5
2
VP562: 10" (79 in.
)
6.3
2
VP563: 12" (113 in.
)
6.6
2
U L
C
US
R

Advertisement

loading

Summary of Contents for VentAHood JCH/B1 Series

  • Page 1 DESIGNER SERIES WALL MOUNT RANGE HOOD JCH/B1 Series Equipped with LED lighting. Not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Recommended OPTIONAL Mounting Height DUCT COVER 30"...
  • Page 2: Warning - To Reduce The Risk Of Fire, Electric Shock, Or Injury To Persons, Observe The Following

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/B1 DESIGNER SERIES WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 3 Ducting Do’s and Don’ts General Requirements • Observe local codes regarding special duct requirements and placement of duct against combustibles. • Using Vent-A-Hood transitions (back page) will ensure proper efficiency. • Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. • Where possible, seal joints with duct tape. • The hood must be ducted to the outdoors without restrictions. Blower Requirements • The single blower unit (B100) requires 6”...
  • Page 4 Installation Details 1) Read all instructions thoroughly before beginning installation. 2) When installing a JCH/B1 wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30” above the cooking surface for optimum performance. 30"...
  • Page 5 Installation Details Continued Connection Diagram (36” - 48” Widths) 1 ¾” 5 ¼” 1 ⁄ ” Wall Side Vent Hole Electrical 6” Outlet 3 ¼” Centerline of Hood 300 CFM B100 Single Blower (Front View) (Top View) Connection Diagram (36” - 48” Widths) 5 ½”...
  • Page 6 Installation Details Continued 5) Remove the shipping tape that is securing the E-Z Clean shield(s) inside the hood. Remove the E-Z Clean shield(s) by lightly pulling it toward the front of the hood. Gently close the back draft damper(s) from the top side of the hood. To remove the blower housing(s), unsnap the suitcase latches (one on each side of the housing).
  • Page 7 Installation Details Continued 11) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12. Note: Wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut a duct access hole in the wall prior to installing the hood. To accomplish this, first remove and set aside the duct cover that was previously installed in Step 8.
  • Page 8 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 ⁄ ” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 3 ¼” 7” 13” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...
  • Page 9 Back Vent Applications (Page 1 of 4) Back Vent K250 B100 B200 B300 B400 Hood Model/Hood Style Diagram (3-1/4” x 10”) (6” Round) (8” Round) (8” Round & 6” Round) (Two 8” Round) K-Series Under Cabinet Hood and Liner Insert Standard 6”...
  • Page 10 Elbow and Transition Heights VP513: 6” Round - 8 1/2” Tall VP561: 8” Round to 6” x 8 1/2” VP559: 3 1/4” x 10” - 4 1/4” Tall When Fully Adjusted to 90 Degrees Rectangular - 7” Tall VP515: 8” Round - 10 3/4” Tall When Fully Adjusted to 90 Degrees Diagram A - Direct Back Vent Diagram B - Off the Top...
  • Page 11 Back Vent Applications (Page 2 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP559: 3 1/4”...
  • Page 12 Back Vent Applications (Page 3 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP513: 6”...
  • Page 13 Back Vent Applications (Page 4 of 4) NOTE: Excluding the SLH6-K, Under Cabinet Range Hood and the KHSLD Liner Insert, all Vent-A-Hood range hoods duct out the top and can be back-vented only by use of transitions and/or elbows. Transition Heights VP513: 6”...
  • Page 14 7” Round VP505 3-1/4” x 12” 6” & 8” to 10” VP551 VP502 8” Round VP506 3-1/4” x 16” Page email: customer_service@ventahood.com website: www.ventahood.com 4/16/2012 Rev. 1 THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE.
  • Page 15: Light Bulbs

    GU10 HALOGEN BULB, 50 WATT P1110 F15/T8 FLUORESCENT BULB, 15 WATT P1120 PAR20 HALOGEN BULB, 50 WATT P1130 Page 4/16/2012 Rev. 1 email: customer_service@ventahood.com website: www.ventahood.com THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE.

This manual is also suitable for:

Jdh/c1 series