Read and Save These Instructions

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction. Switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and local code authorities.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L110 0808A
WALL MOUNT HOOD
DUCTWORK
Page 1
U L
C
US
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WALL MOUNT HOOD and is the answer not in the manual?

Questions and answers

Summary of Contents for VentAHood WALL MOUNT HOOD

  • Page 1: Read And Save These Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 Ducting Do’s and Don’ts NEVER restrict the duct size. The single blower unit (B100) requires 6” round duct or equivalent (28 square inches), and the dual blower unit (B200) requires 8” round duct or equivalent (50 square inches). When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined.
  • Page 3 Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing a wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30"...
  • Page 4 Installation Details Continued Connection Diagrams (30”- 48” Widths) Connection Diagrams (30”- 54” Widths) 1 ¾” 5 ¼” 1 �⁄�” 5 ½” 5 ¼” Wall Side Wall Side Vent Vent Holes Hole 1 ¾” Electrical 8” Outlet Electrical 6” Outlet Centerline 3 ¼”...
  • Page 5 Installation Details Continued 8) Install an appropriate 1/2" UL listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (on previous page) for further details on electrical placement.
  • Page 6 Installation Details Continued 14) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 15. Method 1: Place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the inside the collar(s) of the exhaust outlet(s). Use duct tape to seal joints. Lift the hood up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection(s) between the elbow(s) and the duct(s) in the wall.
  • Page 7 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 �⁄�” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 7” 13” 3 ¼” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...

Table of Contents