Carrier 58CTW Product Data page 10

Performance 80 two---stage variable---speed 4---way multipoise induced---combustion gas furnace input capacities: 45,000 thru 135,000 btuh series 110
Table of Contents

Advertisement

AIR DELIVERY—CFM (With Filter)* (Continued)
Cooling Switch Settings
Unit Size
SW2-8
SW2-7
110-22
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Maximum Clg Airflow
High Heat Airflow
Low Heat Airflow
Cooling Switch Settings
Unit Size
SW2-8
SW2-7
135-22
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Maximum Clg Airflow
High Heat Airflow
Low Heat Airflow
1.
Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF.
Set both SW1-5 and SW2-2 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1-5 to ON and SW2-2 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW2-2 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton).
2.
Maximum cooling airflow is achieved when switches SW2-6, SW2-7, SW2-8 and SW1-5 are set to ON, and SW2-2 is set to OFF.
3.
All heating CFM's are when low heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to
OFF
4.
Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not
recommended because high-heat operation will be above 1.0 ESP.
5.
All airflows on 21" casing size furnaces are 5% less on side return only installations.
6.
Side returns for 24.5" casing sizes require two sides, or side and bottom, to allow sufficient airflow at the return of the furnace.
SW2-6
0.1
0.2
OFF
OFF
2055
2000
OFF
ON
855
755
ON
OFF
1060
985
ON
ON
1250
1180
OFF
OFF
1445
1380
OFF
ON
1685
1630
ON
OFF
2055
2000
ON
ON
2465
2415
2
2465
2415
3
2105
2055
3
1740
1685
SW2-6
0.1
0.2
OFF
OFF
2040
1985
OFF
ON
850
740
ON
OFF
1040
960
ON
ON
1245
1170
OFF
OFF
1450
1385
OFF
ON
1670
1605
ON
OFF
2040
1985
ON
ON
2520
2455
2
2520
2455
3
2260
2205
3
2005
1950
External Static Pressure (ESP)
0.3
0.4
0.5
0.6
1950
1900
1840
1790
See note 4
875
800
700
1095
1025
925
860
1320
1235
1175
1100
1560
1505
1445
1375
1950
1900
1840
1790
2365
2305
2230
2140
2365
2305
2230
2140
2005
1955
1895
1850
1620
1560
1505
1440
External Static Pressure (ESP)
0.3
0.4
0.5
0.6
1930
1880
1830
1775
See note 4
865
755
1080
1005
920
835
1305
1245
1180
1085
1540
1480
1425
1350
1930
1880
1830
1775
2405
2350
2290
2195
2405
2350
2290
2195
2150
2100
2045
1985
1895
1845
1790
1735
10
0.7
0.8
0.9
1.0
1740
1675
1625
1565
See note 4
775
715
See note 4
1035
955
900
825
1320
1265
1195
1140
1740
1675
1625
1565
2045
1925
1805
1655
2045
1925
1805
1655
1795
1735
1665
1580
1385
1325
1260
1205
0.7
0.8
0.9
1.0
1715
1660
1595
1510
See note 4
750
See note 4
1015
935
880
805
1280
1220
1135
1070
1715
1660
1595
1510
2090
1965
1815
1615
2090
1965
1815
1615
1925
1855
1745
1600
1675
1620
1550
1475