Vogelzang International TR004 Owner's Operation And Instruction Manual
Vogelzang International TR004 Owner's Operation And Instruction Manual

Vogelzang International TR004 Owner's Operation And Instruction Manual

Masonry fireplace insert or zero-clearance (metal) fireplace insert

Advertisement

Owner's Operation and Instruction Manual
US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE
CAUTION!
Please read this entire manual be-
fore you install and use your new
heater. Failure to follow instructions
may result in property damage,
bodily injury, or even death.
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO
ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
MODEL: TR004
Fireplace Insert
Masonry Fireplace Insert or Zero-Clearance (metal) Fireplace Insert
SAFETY TESTED TO UL 1482-2010
WASHINGTON STATE APPROVED
DO NOT use this appliance in a mobile home, manu-
factured home, trailer, or tent.
SAVE THESE INSTRUCTIONS
Vogelzang
227 Industrial Park Rd.
P.O. Box 151
South Pittsburg, TN 37380
SAFETY NOTICE:
If this heater is not properly installed, a house fi re may
result. For your safety, follow the installation instructions.
Contact local building or fi re offi cials about restrictions
and installation in your area.
852137

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TR004 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vogelzang International TR004

  • Page 1 Owner’s Operation and Instruction Manual MODEL: TR004 Fireplace Insert Masonry Fireplace Insert or Zero-Clearance (metal) Fireplace Insert SAFETY TESTED TO UL 1482-2010 WASHINGTON STATE APPROVED US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE DO NOT use this appliance in a mobile home, manu- factured home, trailer, or tent.
  • Page 2: Safety Instructions

    CONGRATULATIONS! You’ve purchased a heater from North America’s oldest manufacturer of wood burning products. By heating with wood you’re helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to pre- serve our wood supply. Plant at least one tree each year. Future generations will thank you. The instructions pertaining to the installation of your wood stove comply with UL-1482.
  • Page 3 TR004 DIMENSIONS 27 1/32 [686.6 mm] 26 11/32 [669.0 mm] 13 5/32 [334.5 mm] 44 7/32 [1123.0 mm] 6.00 INSIDE 22 1/4 [565.0 mm] 21 13/16 [554.0 mm] 4 11/16 [118.8 mm] 15 1/2 [394.0 mm] Ussc...
  • Page 4: Pre-Installation Requirements

    PRE-INSTALLATION REQUIREMENTS 6. Fireplace Opening Dimensions. FIREPLACE CONDITION AND A. Minimum Width ....... 29˝ [737mm] ZERO CLEARANCE REQUIREMENTS B. Minimum Height ......23˝ [584mm] A masonry fi replace must meet minimum code require- ments, National Fire Protection Association, (NFPA) 211, C.
  • Page 5: Floor Protector

    PRE-INSTALLATION REQUIREMENTS continued... a. Existing fuel-fi red equipment shows evidence of The chimney must also meet minimum and maximum back puffi ng, smoke roll-out, ineffi cient operation, cross sectional requirements. For that reason a continu- or excessive smell in the living area. ous 6˝...
  • Page 6: Assembly Instructions

    ASSEMBLY INSTRUCTIONS TOOLS AND MATERIALS REQUIRED FOR INSTALLATION TOOLS MATERIALS • Pencil (NOTE: The following items are NOT included with your stove.) Flooring Protection: as specifi ed herein. • 6 foot Folding Ruler or Measuring Tape Chimney Liner: Continuous stainless steel chimney liner •...
  • Page 7 ASSEMBLY INSTRUCTIONS continued... 11. Bolt the top panel (1) to the side panels (2) so the top 15. The surround assembly is held in place with two surfaces are fl ush to one another using items 3 and 4. springs at the top of either corner of the appliance (fi...
  • Page 8: Chimney Specifications

    CHIMNEY SPECIFICATIONS IMPORTANT INSTALLATION POINTS This appliance must be connected to a listed Stainless Steel Liner, that meets UL1777, which extends from the 1. Size chimney fl ue to appliance collar. This stove re- collar to the chimney cap according to the specifi cations quires a minimum 6”...
  • Page 9: Fuel Recommendations

    FUEL RECOMMENDATIONS WOODSTOVE UTILIZATION Your heating appliance was designed to burn wood only; no other materials should be burned. Waste and other fl am- mable materials should not be burned in your stove. Any type of wood may be used in your stove, but specifi c varieties have better energy yields than others.
  • Page 10: Optimal Fuel Consumption

    OPERATING INSTRUCTIONS OPTIMAL FUEL CONSUMPTION CAUTIONS: HOUSE FIRE HAZARDS This appliance is designed to get the most effi cient transfer of • DO NOT STORE WOOD ON FLOOR PROTECTOR, heat energy from the wood fuel and radiate it into your living UNDERNEATH STOVEPIPE(S) IF APPLICABLE, environment.
  • Page 11: Adding Fuel

    OPERATING INSTRUCTIONS continued... ADDING FUEL NOTICE - INITIAL BURNS TO CURE PAINT If the embers are not hot and glowing, rake the embers to BECAUSE OF THE HIGH OPERATING TEM- the front of the appliance, close the door and adjust the PERATURES, THIS APPLIANCE IS COATED air inlet control to the wide open position.
  • Page 12: Chimney Maintenance

    CHIMNEY MAINTENANCE 4. A small hot fi re is preferable to a large smoldering one CAUTION: that can deposit creosote within the heating system. SLOW BURNING FIRES FOR EXTENDED USE OR 5. Establish a routine for the handling of fuel, wood BURNING GREEN WOOD MAY CAUSE EXCESSIVE burner and fi...
  • Page 13: Service Hints

    SERVICE HINTS ASH REMOVAL AND DISPOSAL GLASS REPLACEMENT Ashes should be removed from the stove every few days 1. Ensure appliance is not in operation and is thoroughly or when ashes get to 2 to 3 inches deep. Always empty cooled.
  • Page 14: Repair Parts

    REPAIR PARTS Part No. Description Qty. Part No. Description Qty. 69660 Complete Door Assembly 88158 Fiber Board, Front 88066 5/8” Rope Gasket 6 ft. 88159 Fiber Board, Rear 891813 Door Glass 88160 Fiber Blanket 88087 Glass Gasket 4 ft. 80598 Blower Assembly 25465 Glass Retainers...
  • Page 15: Floor Protector

    FLOOR PROTECTOR To calculate R-Values for alternative methods, see below for calculation methods. Alternate materials may be rated with C-factor (Thermal Conductance) or k-factor (Thermal Conductivity) ratings which must be converted to R-value to determine if the alternate material meets the tested requirements. The following instructions provide the proper information and formulas for conversion to R-value.
  • Page 16: Certification Label

    Certification Label US Stove Company 227 Industrial Park Road South Pittsburg, TN 37380 2012 2013 2014 852138 Ussc...
  • Page 17 Notes / Sketches Ussc...
  • Page 18 WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMA- TION AS SHOWN IN THIS LIST: 1. THE PART NUMBER 2. THE PART DESCRIPTION 3. THE MODEL NUMBER: TR004 4. THE SERIAL NUMBER:____________________ Vogelzang 227 Industrial Park Rd. P.O. Box 151...
  • Page 19   Fold Here Fold Here Fold Here PLACE STAMP HERE Vogelzang 227 Industrial Park Rd. P.O. Box 151 South Pittsburg, TN 37380 Ussc...
  • Page 20 WARRANTY INFORMATION CARD Name__________________________________________ Telephone #: (_____)_____________ City____________________________________________ State_______ Zip_________________ Email Address __________________________________________________________________ Model # of Unit________________________________ Serial #___________________________ Fuel Type: Wood Coal Pellet Gas Other _________________________ Place of Purchase (Retailer)______________________________________________________ City____________________________________________ State_______ Zip_________________ If internet purchase, please list website address___________________________________ Date of Purchase _______________________________________________________________ Alternative Heat Main Heat Source...

Table of Contents