Vogelzang International Colonial TR004 Owner's Manual

Vogelzang International Colonial TR004 Owner's Manual

High efficiency fireplace insert, epa certified (4.02grams/hr)

Advertisement

COlONial
firEplaCE iNsErT
model TR 004 Owners manual
This appliance meets U.S. Test
Standard: UL 1482-2006
DO NOT USE THIS APPLIANCE IN A
mOBILE HOmE, mANUFACTURED HOmE,
TRAILER, OR TENT – NO EXCEPTIONS!
TR004M | 11102010.0
HigH EffiCiENCy
EPA Certified (4.02grams/hr)
(save this manual for future reference)
READ ALL INSTRUCTIONS CAREFULLY
BEFORE STARTING THE INSTALLATION
OF OR OPERATING THIS APPLIANCE.
FAILURE TO FOLLOw INSTRUCTIONS
mAY RESULT IN PROPERTY DAmAGE,
BODILY INjURY, OR EvEN DEATH.
REFER TO mARkINGS ON
STOvE LABELS FOR
ADDITIONAL INFORmATION.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
TR004 COLONIAL™ |
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Colonial TR004 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vogelzang International Colonial TR004

  • Page 1 DO NOT USE THIS APPLIANCE IN A REFER TO mARkINGS ON mOBILE HOmE, mANUFACTURED HOmE, STOvE LABELS FOR TRAILER, OR TENT – NO EXCEPTIONS! ADDITIONAL INFORmATION. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 1 TR004M | 11102010.0...
  • Page 2: Safety Precautions

    SAFETY INSTRUCTIONS SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED A HOUSE/BUILDING FIRE mAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERmITS, RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA. READ ALL INSTRUCTIONS CAREFULLY. (See Chimney Maintenance, page 12). 1.
  • Page 3 SAFETY INSTRUCTIONS continued… sons, especially young children should be alerted NOTE: A PROFESSIONAL, LICENSED HEAT- to the hazards from high surface temperatures. ING AND COOLING CONTRACTOR SHOULD Keep away from a hot appliance to avoid burns or BE CONSULTED IF YOU HAvE qUESTIONS clothing ignition.
  • Page 4: Table Of Contents

    TAblE OF CONTENTS Safety Precautions ..................2 – 3 Product Dimensions ................... 5 Pre-installation Requirements ................6 Chimney Condition ..................6 minimum Clearances to Combustible materials ........6 venting ......................7 Floor Protector ................... 7 Tools and materials Required for Installation ........... 8 Assembly Instructions Chimney Connection ..........
  • Page 5: Product Dimensions

    COlONIAl™ dImENSIONS Page 5 TR004M | 11102010.0 TR004 COLONIAL™ |...
  • Page 6: Pre-Installation Requirements

    PRE-INSTAllATION REqUIREmENTS FIREPLACE CONDITION & 5. Fireplace Opening Dimensions. ZERO CLEARANCE REqUIREmENTS A. Minimum Height ..23˝ A masonry fireplace must meet minimum code B. Minimum Widths ..29˝ requirements, National Fire Protection Association, C. Minimum Depth ...14˝ (NFPA) 211, or the equivalent for a safe installation. Contact a professional, licensed installer, your local building inspector or the local fire authority for the requirements in your area.
  • Page 7: Venting

    a. Existing fuel-fired equipment show evidence The chimney must also meet minimum and maximum of back puffing, smoke roll-out, inefficient cross sectional requirements. For that reason a con- operation or excessive smell in the living tinuous 6˝ stainless steel liner from the flue collar to area.
  • Page 8: Tools And Materials Required For Installation

    ASSEmblY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND mATERIALS REqUIRED FOR INSTALLATION tools materials • Pencil (NOTE: The following items are NOT included with your stove) •...
  • Page 9: Chimney Connection

    panels, a top panel and a decorative trim frame. 15. The faceplate assembly is held in place with two springs at the top of either corner of the insert 11. Bolt the top panel (1) to the side panels (2) so the (figure 6).
  • Page 10: Chimney Connections/Draft

    ChImNEY SPECIFICATIONS This appliance must be connected to a listed Stainless to a masonry chimney are detailed in the installation Steel Liner, that meets UL1777, which extends from the instructions. If the fireplace chimney must go through collar to the chimney cap according to the specifications a combustible wall before entering the main chimney, listed on the previous pages.
  • Page 11: Operating Instructions

    OPERATING INSTRUCTIONS This appliance is designed to burn CAUTION: HOUSE FIRE HAZARDS wOOD FUEL ONLY! • Do NoT SToRE wooD oN FLooR PRoTEC- Hardwood, 17” to 19”, should be split and air dried TOR, UNDERNEATH STOvEPIPE(S) IF AP- (seasoned) for 6 months to obtain maximum burning ef- PLICABLE, OR ANYwHERE wITHIN mINImUm ficiency.
  • Page 12: Starting A Fire, Adding Fuel

    OPERATING INSTRUCTIONS continued . . . secondary flames then slowly reset the air control to the 7. Once fuel has been loaded, close the door and desired setting. Initially it may take several attempts to leave the air inlet control fully open until fire is well figure your insert out.
  • Page 13: Blower Operation

    OPERATING continued . . . ChImNEY mAINTENANCE Blower Operation Preventing Creosote Buildup The variable speed blower circulates air warmed by the 1. Burn with air control open for several minutes at firebox into the living area to distribute the heat more numerous intervals throughout the day during the evenly.
  • Page 14: Glass Care & Replacement, Glass Gasket Replacement

    SERvICE hINTS house or tree falls on top of the chimney like water 6. Trim to length and butt ends together. over a dam, beating down the smoke. The top of 7. Replace glass into door, being sure not to over- the chimney should be at least three (3) feet above tighten screw and clip.
  • Page 15: Parts - Colonial

    PARTS - TR004 COlONIAN hIGh-EFFICIENCY INSERT When ordering missing or replacement parts, always give the model Number of the insert, Part Number, and Part description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. Ref.
  • Page 16: Parts - Glass Door (Glass Replacement)

    PARTS - TR004 COlONIAl hIGh-EFFICIENCY INSERT When ordering missing or replacement parts, always give the model Number of the insert, Part Number, and Part description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 24, 25, 26 Ref.
  • Page 17: Floor Protector Calculations

    FlOOR PROTECTOR mATERIAl CAlCUlATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 3, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
  • Page 18 “FOR GOD SO LOvED THE wORLD THAT HE GAvE HIS ONLY BEGOTTEN SON, THAT wHOEvER BELIEvES IN HIM SHALL NoT PERISH BuT HAvE ETERNAL LIFE” jOHN 3:16 mADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...

Table of Contents