No.
Part name
1) Perform the common procedure
Capacitor for
2
compressor
2) Remove the fixing screw and the capacitor
3) Disconnect the lead wires.
1) Perform the common procedure
Capacitor for
3
2) Remove the fixing screw
fan motor
3) Disconnect the lead wires.
Procedures
band.
(1-Screw ∅4 x 10L)
− 70 −
FILE NO. SVM-06001
.
1
Screws
∅4 x 8L
.
1
Capacitor for fan motor
Remarks
Capacitor band
Capacitor
for
compressor
Screws
Ø4 x10L