(3) The indoor heat exchanger restricts revolving
speed of the fan motor to prevent a cold draft. The
upper limit of the revolving speed is shown in
Fig. 7-2-8 and Table 7-2-1.
13NKH Series
°C
45
34
44
33
32
21
31
20
*2
A+0
A+0
A− 8
A− 8
*6
*5
Fig. 7-2-8 Cold draft preventing control
NOTES :
*1: The fan stops for 2 minutes after thermostat-OFF
*2: A is 24°C when the preset temperature is 24°C or
more and A is the preset temperature when it is
under 24 °C.
*3: SL means Super Low.
*4: Calculated from difference in motor speed
between SL and H.
*5 and *6:
Fan
*5
speed
Starting period
·
AUTO
Up until 12 minutes
passed after starting
the unit
·
From 12 to 25 minutes
passed after starting
the unit and room
temperature is 3 °C
lower than preset
·
temperature
·
Manual
Room temperature
-
(L
H)
< Preset temperature
Table 7-2-1
Manual
AUTO
(One of 5 steps)
-
*4
L H (Up to
seting speed)
SL
*3
SL*1
Stop
*6
Stabilized period
·
From 12 to 25 minutes
passed after starting
the unit and room
temperature is
between preset
temperature and 3 °C
lower than preset
temperature
·
25 minutes or more
passed after starting
the unit
·
Room temperature
Preset temperature
-
-
3.5 °C
4 °C
7-2-5. Automatic operation
([MODE] button on the remote control is set
to the automatic operation.)
(1) One of 3 operations (Cooling, Fan only or Heating)
is selected according to difference between the
preset temperature and the room temperature at
which the automatic operation has started, as
shown in Fig. 7-2-9. The Fan only operation
continues until the room temperature reaches a
level at which another mode is selected.
(2) Temporary Auto
When the [RESET] button on the indoor unit
is pushed, the preset temperature is fixed at 24 °C
and the indoor unit is controlled as shown in
Fig. 7-2-9.
°C
The louver moves to the position same
as Hi POWER operation.
+4
0
-
1
Heating operation
NKH Series
.
-
-
26
FILE NO. SVM-06001

Cooling operation

Cooling operation

Fan only operation

NK Series
Fig. 7-2-9