5-4. RAS-10NKP-HX / RAS-10N2A-HX

Cooling
0.39 m
(Connecting pipe)
9.52
P
O.D.:9.52 mm
Packed valve
( ∅ 9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
RM5510GNE94
Heat exchanger
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.56
0.68
0.48
− 20 −
FILE NO. SVM-06001
T1
Packed valve
(∅6.35)
Capillary tube
∅ 1.5 x 1000l
Refrigerant
R22 : 0.75 kg.
Mark (
) means check points of Gas Leak.
Fan speed
(indoor)
12.0
High
17.0
High
5.0
Low
0.49 m
(Connecting pipe)
∅ 6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15