Thermo-Dynamics Boiler TDE-10 Installation And Maintenance Manual

Electric a compact, versatile, easy-to-use heat source for forced hot water systems

Advertisement

Quick Links

THERMO-DYNAMICS
Electric Boiler
A Compact, Versatile, Easy-to-Use
Heat Source for Forced Hot Water Systems
Installation and Maintenance Manual
Thermo-Dynamics oiler Company
ROUTE 61 • P.O. BOX 325 • SCHUYLKILL HAVEN, PA 17972
(570) 385-0731
FAX (570) 385-5304

Advertisement

Table of Contents
loading

Summary of Contents for Thermo-Dynamics Boiler TDE-10

  • Page 1 THERMO-DYNAMICS Electric Boiler A Compact, Versatile, Easy-to-Use Heat Source for Forced Hot Water Systems Installation and Maintenance Manual Thermo-Dynamics oiler Company ROUTE 61 • P.O. BOX 325 • SCHUYLKILL HAVEN, PA 17972 (570) 385-0731 FAX (570) 385-5304...
  • Page 2: Energy Efficient

    Thermo-Dynamics TDE Electric Boiler he Thermo-Dynamics TDE Electric Boiler CLEAN. is compact, clean, quite, and does not require a storage facility or chimney allowing convenient The TDE heating system eliminates the need for installation near the point of use. The TDE electric fuel storage facilities and chimneys.
  • Page 3 Designed for Reliable Home Heating Comfort A Summary of Practical Applications • Solar Heating Systems. Every active solar heating system needs a reliable back-up heating unit that can perform through long periods of adverse weather. The TDE is UL listed as a central heating boiler, thus providing the power needed for total solar security.
  • Page 4 No. of 5KW Watts Approx. Boiler Input Gross *Net Total Heater Circuit Shipping Size Rating Output Output Elements 240V Wgt. Lbs. TDE-10 34,000 34,000 30,000 – – 10,000 TDE-15 51,000 51,000 44,000 – 15,000 TDE-20 68,000 68,000 59,000 – 20,000...
  • Page 5 CAUTION: READ ME FIRST Check the unit for shipping damage. If there is any evidence of damage, including damage to the exterior jacket, you should contact your freight company immediately and file a claim. Do not install the boiler. Proper selection of the right size TDE, or any heating device, requires an accurate heat balance performed by a qualified heating professional.
  • Page 6: Installation

    INSTALLATION installed in accordance with the manufacturer’s recommendations. 1. Carefully remove unit from shipping A conventional expansion type of carton. Remove the boiler jacket by tank may be connected to the 1/2" NPT fitting in the boiler top. If a removing the jacket assembly screws pressure type tank is used the 1/2"...
  • Page 7: Operation

    9. Circuit breaker size is 60 amps per Caution: The Thermostat, ground wire heater circuit and 15 amps for the and power wires are the only connec- circulator pump and control circuit. tions that should be made to the TDE. The 24 volt control circuit is pro- Do not supply power to any other sys- tected with a 2 amp ferrule fuse.
  • Page 8: Sequence Of Operation

    used. If equipped with manual feed, When installation is complete and close the system water supply the system is operating satisfac- valve when a pressure reading of torily, close the cabinet door and 12 psi is obtained. The purge valve re-install the door holding screw may have to be bled to reduce to prevent accidental or uninten-...
  • Page 9: Maintenance

    If the water temperature reached 200°, free to prevent introduction of air dur- due to a failure of the Operating Control ing operation. Limit, for example, the High Limit safety will shut off all elements at once. Staging The TDE-15, 20, 25 and 30 can be The High Limit Safety is set at 200°...
  • Page 10 allow two of the heater elements to When using outside temperature to come on after time delay if one set stage, start by setting the first staged point is reached and the remaining thermostat at 40°F. Set a second ther- heaters will be energized if the other set mostat at 20°F if a second stage is used.
  • Page 17 PIPING DIAGRAM, DIAPHRAGM TYPE EXPANSION TANK PIPING DIAGRAM, CONVENTIONAL EXPANSION TANK...
  • Page 19 Thermo-Dynamics Electric Boiler Power Supply Wire Sizes Split Power Supply Wire Sizes AWG Copper Model Circuit 1 Circuit 2 Circuit 3 Equipment GRD. Single Power Supply Model Wire Size...
  • Page 20 T E ELECTRIC BOILER WARRANTY A. Full Three Year Warranty. Thermo-Dynamics warrants the T E boiler units are free from defects in material and workmanship for 3 years from date of installation. If any parts are found to be defective in manufacture, Thermo-Dynamics will repair or replace them at Thermo- Dynamics’...