31 RE-ASSEMBLY
Re-assemble the boiler in the following order :
1. Refit the flue baffle into the boiler flueway, ensuring that
they are correctly repositioned. Refer to Frame 6.
2. Refit the flue cleanout cover, renewing any damaged or
deteriorating sealing gasket.
3. Refit the casing top panel.
4. Reconnect the electrical wiring and refit the controls
panel, ensuring that the thermostat phial and phial
retaining clip are correctly located in the thermostat pocket
and secured by the split pin. Refer to Frame 27.

32 GAS PRESSURE ADJUSTMENT

1. Pilot pressure.
Pilot adjustment is factory set to maximum and no
adjustment is possible,
2. Main burner pressure.
After servicing, reference should be made to Table 2,
which quotes details of the rated output with the related
burner pressure and heat input.
24
SERVICING
5. Check the sightglass in the front plate - clean or renew as
necessary.
6. Renew any damaged or deteriorating front plate gasket.
7. Refit the burner and controls assembly.
8. Reconnect the gas service cock.
9. Refit the grille assembly.
Any required adjustments should be made using the
pressure adjustment screw. Refer to Frame 23, 'Initial
Lighting'.
Refit the lower front panel in reverse order. Refer to
Frame 27.
Mexico Slimline CF 3/40 & 3/50 -