Generator - PDQ Yachts 36 Capella Owner's Manual

Table of Contents

Advertisement

Caution: The switch setting CONFIGURE should never be used in
normal operation.
internal data set at the factory.
For further information, consult the manufacturer's information in the Owner's Kit.
The Entec West Diesel Generator, model EW-4200, is rated at 120 volts +/- 5%, 35
amps, and 60 Hz +/- 1.2%. It is capable of starting motors under load, equivalent to a
16,000 BTU air conditioner, plus a second 12,000 BTU conditioner. The engine is
water-cooled by seawater with a heat exchanger and a closed loop of 50/50 fresh water
and permanent anti- freeze.
The generator remote controls comprise the switch START/RUN/OFF, and indicator
lights for oil pressure and water temperature.
Battery – The generator does not produce DC to charge its starting battery. This is
done by the DC system, through the Inverter/Charger with the charge function
ENABLED, controlled by an "echo" charger.
Electric starting is provided with manual back up. The normal start procedure is as
follows:
1. Turn off the AC loads at the main panel,
2. Warm up for 2-3 minutes,
3. Switch to GEN mode and add AC loads gradually.
Normal stopping is:
1. Switch off AC loads,
2. Switch off GEN mode
3. Cool off for 3-5 minutes and stop.