O P E R A T I N G I N S T R U C T I O N S
Select-A-Charge Battery Chargers
models: SCP, SCPX, SCS, SCSX, SCX
For Industrial Use:
Designed for gel, wet cell, AGM, and Lithium Ion batteries
(Lithium ion applications must be factory programmed)
Quick Charge Corp.
800 658-2841
e-mail
quickcharge@icnet.net
www.quickcharge.com
Made in the U.S.A
101712

Advertisement

loading

Summary of Contents for Quick Charge SCP

  • Page 1 O P E R A T I N G I N S T R U C T I O N S Select-A-Charge Battery Chargers models: SCP, SCPX, SCS, SCSX, SCX For Industrial Use: Designed for gel, wet cell, AGM, and Lithium Ion batteries (Lithium ion applications must be factory programmed) Quick Charge Corp.
  • Page 3 If your charger is programmed for Lithium Ion batteries the display will read “FC” Final Charge instead of 80% To discontinue charging, switch the power off, and disconnect battery. EQUALIZATION: When using multiple batteries in a series string, cells become uneven during charge and discharge cycles.
  • Page 4 SAFETY INFORMATION AC WIRING: Before making AC connections, refer to the requirements on the charger ID label. If your charger is not equipped with an AC plug, for example, a 230 volt charger, have a qualified electrician install one. To reduce the risk of fire, use this charger only on branch circuits that are protected by a circuit breaker or fuse, and that are adequate to carry the power drawn by the charger.
  • Page 5: Other Safety Information

    OTHER SAFETY INFORMATION Do not use charger if it shows signs of physical stress, or if DC output leads or connector feel hot when used. Do not disconnect the DC output clamps, or connector from the batteries when the charger is on. The resulting arcing could cause the batteries to explode.
  • Page 6 failure. Re-charge batteries as soon as possible after a deep discharge, but not if they are warm, allow a cooling down period. Provide adequate ventilation when charging batteries. Chargers can ignite flammable materials and vapors. Do not use near fuels, grain, dust, solvents, or other flammables.
  • Page 7 REPROGRAMMING There are 5 charge profiles, and 5 programming adjustments that can be made to the profiles. The profiles are: F1 is a single stage float profile generally used for gel and starting type batteries. There are no adjustments available to this profile. F2 is a two stage profile for deep cycle wet cell batteries.
  • Page 8 r1 when set to the F2 profile, charge will terminate, and the battery will be checked weekly, if the voltage falls to a predetermined level, the charger will recycle and bring the battery(s) back up. To change the profile: Be firm and deliberate when pressing the button.
  • Page 9: Troubleshooting

    TROUBLESHOOTING Symptom Cause Corrective Action When plugged into AC Connected reverse to Correct polarity, or power the LED flashes battery, or not connected connect to battery. On red/green, and a 0 on to battery. chargers having a black display. and white wire, white is positive.
  • Page 10 When powered up the The battery is very low, Leave connected, it may LED is solid red with a and the charger is in a take hours, but if the yellow flash, and slow charge phase until voltage rises even a little displaying 02.
  • Page 11 The cycle ends with Er An incomplete cycle. The batteries are too big showing, and a The batteries did not for the charger. green/yellow flashing reach minimum voltage LED. requirements, and the The batteries have charger bulk timed out. defective cells, and cannot make minimum voltage.