INTRODUCTION:
Designed for group charging starting batteries, gel batteries, AGM batteries, and wet cell deep cycles
in parallel. Current is adjustable from 1 to 50 amps. Voltage from 13.0- 16.0.
INITIAL INSTALLATION:
Before making AC connections, refer to the AC requirements labeled on the charger ID tag. If your charger is
not equipped with an AC plug, for example, a 220 volt charger, have a qualified electrician install one.
CAUTION: To reduce the risk of fire, use this charger only on circuits provided with a maximum of 20
ampere branch circuit protection (circuit breaker or fuse), In accordance with the National
Electric Code, ANSI/NFPA 70, and all local codes and ordinances.
GROUNDING INSTRUCTIONS:
This battery charger must be grounded to reduce the risk of electric shock. If the charger is equipped with a
grounding type plug, it must be plugged into a nominal 115 volt, 60 Hertz circuit. If the charger is supplied with
no plug, have a qualified service person install one.
WARNING: Improper connection of the equipment grounding conductor can result in a risk of an
electric shock. DO NOT USE THIS CHARGER ON A TWO POLE UNGROUNDED
OUTLET OR ATTEMPT TO BREAK OFF THE GROUND PRONG FOR USE ON
A RECEPTACLE OR EXTINSION CORD NOT HAVING A GROUND.
The use of an extension cord with this charger should be avoided. The use of an improper extension cord could
result in a risk of a fire or electric shock. If an extension cord must be used, make sure it is in good condition.
Use a three conductor cord no smaller than 14 AWG. And keep it as short as possible. Locate all cords so that
they will not be stepped on, tripped over, or otherwise subjected to damage or stress.
Do not operate this charger if it shows any signs of physical damage.
PROPER CARE AND USE OF BATTERIES:
CAUTION: Always wear protective eye shields and clothing when working with batteries. Batteries
contain acids which can cause bodily harm. Do not put wrenches or other metal objects
across the battery terminal or battery top. Arcing or explosion of the battery can result. Do
not wear jewelry when working around batteries. Arcing can cause sever burns.
Quick Charge Corp. 1032 S.W. 22
I N S T R U C T I O N S
QPA12v/50A Parallel Charger
nd
St. Oklahoma City, OK. 73109 800 658-2841 Fax (405) 632-5667 www.quickcharge.com

Advertisement

loading

Summary of Contents for Quick Charge QPA

  • Page 1 Arcing or explosion of the battery can result. Do not wear jewelry when working around batteries. Arcing can cause sever burns. Quick Charge Corp. 1032 S.W. 22 St. Oklahoma City, OK. 73109 800 658-2841 Fax (405) 632-5667 www.quickcharge.com...
  • Page 2 New batteries will not deliver their full performance until after several cycles. The tops of the batteries and battery hold downs must be kept clean and dry at all times to prevent excessive self discharge and flow of current between the battery post and frame. Maintain the proper electrolyte level by adding water when necessary.
  • Page 3 PREPERATION: Determine how many batteries you want to charge. You have 50 amps of capacity which will be divided between the number of batteries on line. For example, if you put 10 batteries on line and turn the rate control wide open, each battery will receive approx.
  • Page 4: Trouble Shooting

    Oklahoma City, OK. 73109 Quick Charge, will at it s option, repair or replace the charger or component in question. The repaired item will then be returned, freight prepaid by Quick Charge. This warranty is void if the charger or component have been altered, changed, or repaired by anyone not authorized by Quick Charge, or if the charger or component, have been subjected to misuse, negligence, or harsh environmental conditions.