For industrial use: designed for gel, wet cell, agm, and lithium ion batteries (lithium ion applications must be factory programmed)

Advertisement

O P E R A T I N G I N S T R U C T I O N S
QP, QPXU Battery Chargers
For Industrial Use
: Designed for gel, wet cell, AGM, and Lithium Ion Batteries
(Lithium ion applications must b e factory programmed)
Quick Charge Corp.
800 658-2841
e-mail
quickcharge@icnet.net
www.quickcharge.com
101712
Made in the U.S.A

Advertisement

Table of Contents
loading

Summary of Contents for Quick Charge QP

  • Page 1 O P E R A T I N G I N S T R U C T I O N S QP, QPXU Battery Chargers For Industrial Use : Designed for gel, wet cell, AGM, and Lithium Ion Batteries (Lithium ion applications must b e factory programmed) Quick Charge Corp.
  • Page 3 NOTE: It does not matter what position the meter switch is in. It is for viewing and not operating. EQUALIZATION: When using multiple batteries in a series string, cells become uneven during charge and discharge cycles. At least once a month perform two charge cycles back to back, this will give a chance for cells that are lagging behind to catch up, and is important to overall battery performance.
  • Page 4 DO NOT USE THIS CHARGER ON A TWO POLE UNGROUNDED OUTLET OR ATTEMPT TO BREAK OFF THE GROUND PRONG FOR USE ON A RECEPTACLE OR EXTENSION CORD NOT HAVING A GROUND. If an extension cord must be used, make sure it is in good condition.
  • Page 5 With wet cell batteries, maintain the proper electrolyte level by adding water when necessary. Never allow the electrolyte level to fall below the top of the battery plates. Electrolyte levels fall during discharge and rise during charging. Therefore, to prevent the overflow of electrolyte when charging, add water only after the batteries have been fully charged, or just enough to cover the plates if discharged.
  • Page 6 Illustration of series and parallel battery connections. Parallel Series When batteries are connected in When batteries are connected in Parallel the battery amp hour Series the voltage is additive and capacity is additive and the the battery amp hour voltage remains the same. capacity remains the same.
  • Page 7 NOTE: The #1 position is designated for batteries requiring long finish rates. If your performance is poor, it could be the batteries are being undercharged. Verify with specific gravity readings on wet cells. US Battery, and Full River are two brands that benefit from longer charge cycles.
  • Page 8 TROUBLES HOOTING Symptom Cause Corrective Action No voltage reading on Connected reverse to Correct polarity, or meter when connected battery, or not connected connect to battery. On to battery, and the LED to battery. chargers having a white flashes red/green. and black wire, white is positive.
  • Page 9 The battery voltage The battery is very low, Leave connected, it may reads well below the and the charger is in a take hours, but if the rating of the battery, and slow charge phase until voltage rises even a little when powered up the the voltage rises to a safe bit, it should recover,...
  • Page 10 QUICK CHARGE QP Battery Chargers “LIMITED WARRANTY” Quick Charge Corporation warrants the QP line of chargers for three (3) years from the date of purchase. After the warranty period, chargers returned to the factory for repair will be charged a minimum rate of $25.00.