OZONE GENERATOR RETROFIT INSTALLATION
The Standard 110 and Premium 110 models of the Urbania spa are manufactured with "Ozone Ready" plumbing.
If you want to install an ozone generator on either of these models, follow the instructions below.
The ozone generator to be installed must be 110 volt and approved for use on residential spas.
1
The electrical cord must have an amp style, 4 pin, male connector with wire locations as follows;
2
Turn all power to the spa off.
3
Remove the equipment access door from the spa.
4
Select the best location in the equipment cavity to install the ozone generator. Depending on its size, you
5
may have to install a custom mounting board or platform for the ozone generator.
There is a piece of ¼" ID vinyl tubing with an in line adaptor that runs through the equipment cavity. Locate
6
this tubing and remove the adaptor. The shorter piece of tubing is connected to the air line channel. It must
be plugged. Connect the longer piece of tubing to the barb connector on the ozone generator.
Remove the front cover of the equipment pack by loosening the two screws at the top of the pack.
7
Connect the electrical cord of the ozone generator to the female amp connector labeled J29 and located on
8
the top, right hand side of the circuit board.
Secure the electrical cord into the cord restraints located on the right side of the equipment pack housing.
9
Replace the front cover of the equipment pack.
10
Turn the power to the spa back on and allow the spa to cycle through the start up procedure.
11
With the pump operating on low speed, ensure that the ozone generator is emitting a bluish green colored
12
glow. Note: The ozone generator will only operate when the pump is operating on low speed.
Ensure that a fine bubble mist is coming from the foot well jets.
13
Replace the spa access door.
14
Any time you change a DIP switch, other than A1, you must reset persistent memory for your new DIP switch
settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly.

PERSISTENT MEMORY RESET