Exhaust Hose Installation - RCA RACP1206 Owner's Manual

Mobile type air conditioners (local air conditioners)
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS (optional)
Foam seal A
(adhesive type)
Fig.14
Window
panel
26.5 ~ 48.0
or
Window
panel
26.5 ~ 48.0
Fig.15
or
Fig.16
Foam seal
Fig.15
Installation in a sliding sash
window
1. Cut the foam seal(adhesive type) to the proper
length and attach it to the window frame,Fig.14.
2. Attach the window slider kit to the window stool.
Adjust the length of the window slider kit according
to the width of window, shorten the adjustable window
kit if the width of window is less than 26.5 inches. Open
the window sash and place the window slider kit on the
window stool. See Fig.15.
3. Cut the foam seal(adhesive type) to the proper
length and attach it on the top of the window.
Shown as in Fig.16.
4. Close the sliding sash securely against the window.
5. Cut the foam seal to an appropriate length and
seal the open gap between the top window sash
and outer window sash. Shown as in Fig.17.
11
INSTALLATION INSTRUCTIONS (optional)

Exhaust hose installation:

The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode.
Fig.18a
Fig.18b
COOL,HEAT(heat pump type) or AUTO
mode
FAN,DEHUMIDIIFY or HEAT(electrical heat type)
mode
1. Install the window Exhaust adaptor B onto the exhaust
hose as shown in Fig.18a. or Fig.18b. Refer to the previous
pages for window kit installation.
Hook
Fig.19
2. Place the Exhaust hose over against the air outlet opening
hook(See Fig.19) and flat the other end(See Fig.20) for
quick installation.
The exhaust hose can be installed into the wall
(Not applicable to the units without adaptor A, expansion
plugs and wooden screws of Accessories ).
1. Prepare a hole in the wall. Install the wall Exhaust adaptor A
onto the wall(outside) by using 4 expansion plugs and
wooden screws, be sure to fix thoroughly. (See Fig.21)
2. Attach the Exhaust hose to wall Exhaust adaptor A.
Fig.20
Note:
Cover the hole using the adaptor cap when not in use.
The duct can be compressed or extended moderately
Expansion plug
position
according to the installation requirement, but it is
desirable to keep the duct length to a minimum.
Adaptor A
Adaptor
IMPORTANT:
cap
DO NOT OVER BEND THE DUCT (SEE Fig.22)
CAUTION:
max 120CM
Make sure that there is no obstacle around the air outlet of
the exhaust hose (in the range of 500mm) in order to the
min 30CM
exhaust system works properly.
Fig.21
Fig.22
Install
Remove
12