PROBLEM
The appliance does
not work
The temperature
inside the appliance is
not low enough (the
compressor operates
continuously)
Water collects at the
bottom part of the
freezer
Excess frost build up
Excess condensation
on outer surface of
your appliance
The appliance makes
too much noise

Troubleshooting

REASON
A gap in the electrical system
circuit
The compressor hardly ever
activates
The door doesn't shut tight or
is opened too often
Appliance is positioned near a
heat source or exposed to
direct sunlight
The ambient temperature is
above +36°C
Air circulation at the back of
the appliance is hampered
The contents touch the back
wall of the interior
The drain opening is clogged
Operating the appliance in an
unheated location (e.g. a
cellar)
Operating the appliance in an
unheated location (e.g. a
cellar)
The freezer is not level
The appliance is touching
another object
www.lec-commercial.co.uk
SOLUTION
1. Make sure the plug is properly
inserted into the socket.
2. Make sure the socket is not faulty
3. Make sure the power supply cord is
not damaged
1. Check to see if the ambient
temperature is below +16°C
1. Rearrange the products so they don't
hamper the door.
2. Shorten the time the door is open for
1. Move appliance away from any area's
where heat sources or direct sunlight
are present
1. Check the appliance is operating at an
ambient temperature that is less than
+36°C
1. Move product further away from the
wall
1. Move the products so they aren't in
contact with the back wall
1. Take the cleaning plug and unclog the
condensate opening
1. Move to a warmer location where
temperature fluctuations are minimal
1. Move to a warmer location where
temperature fluctuations are minimal
1. Place the appliance on an even
surface or use adjustable feet
1. Reposition the appliance so it is at
least 2cm apart from any other
objects