2.1

ELECTRIC FRY-TOP DATA PLATE

The technical data plate is under the bottom
edge of the instrument panel.
2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES

The following regulations must be observed during installation:
- Current accident and fire regulations.
- The regulations of the electric power supply company.
- Health regulations.
- Electrical systems standards.
2.3

PLACE OF INSTALLATION

- The unit should be installed in a room with adequate ventilation.
- Install the unit in compliance with the safety regulations.
2.4

POSITIONING

- The various units may be installed separately or combined with other units in the DOMINA range.
- This unit is not suitable for encasing.
- The distance from the side walls must be at least 10 cm.; should the distance be less or the material of the walls or floor be
flammable, it is vital to install heat insulation.
2.5

ELECTRICAL CONNECTION

The electrical connection must be made in compliance with CEI standards, only by authorized and skilled personnel.
Firstly, check the data given in the technical data table of this manual, on the data plate and in the wiring diagram. The
envisaged connection is of the fixed type.
IMPORTANT: A multi-polar mains cut-off device must be provided upstream from each oven, with a contact gap of at least
3 mm., for example:
- a manual switch of suitable capacity, equipped with fuses
- circuit breaker with relevant miniature circuit breakers.
2.5.1

EARTHING

It is vital to earth the oven.
Connect the terminals marked by the symbols (
complying with the regulations in force.
SPECIFIC WARNINGS
The electrical safety of this unit is assured only when it is connected correctly to an effective earthing system as stated in
the current electrical safety standards; the manufacturer accepts no liability if these safety standards are not met.
It is necessary to verify this fundamental safety requisite and, in case of doubt, ask for the system to be tested thoroughly by
professionally qualified personnel.
The manufacturer cannot be deemed responsible for any damage caused by failure to earth the system.
CAUTION: NEVER CUT THE EARTH WIRE (yellow-green).
2.5.2

EQUIPOTENTIAL SYSTEM

The oven must be included in an equipotential system whose efficiency must be checked according to the standards in force.
The screw marked with the "Equipotential" label is on the back near the cable clamp.