Before programming the thermostat press the + & – AND L & M buttons
simultaneously to reset the unit (Fig.1)
Setting the Clock and Day
1) CLOCK - Press PROG (Fig.2) to begin programming
Use + or – buttons (Fig.3) to adjust the TIME (Fig.4)
2) DAY - Press PROG again (Fig.2)
Use + or – buttons (Fig.3) until correct DAY is shown (MO = Monday) (Fig.5)
Accepting the Factory Pre-settings
The TP9 has pre-set times already programmed in for controlling the heating
and hot water, which often suit most people (see Table below & Fig.12 over).
To accept these settings press the PROG button until the time appears in the
display and colon begins to flash - the unit is now in RUN mode (Fig.6).
If you wish to alter these settings follow instructions below.
Mon-Sun (24 hour mode)
Mon-Fri (5/2 day mode)
Event
Time
Temp°C
1
06.30
2
08.30
3
12.30
4
13.30
5
17.30
6
22.30
Your installer will have set your unit to operate in one of the following modes:
5/2 day - one set of programmes for weekdays and another for weekends
24 hour - one set of programmes for the whole week
Programming your CENTRAL HEATING
For Days 1-5 (weekdays)
a) Press PROG (Fig.2) 3 times to show the 1
(Event 1 Days 1,2,3,4,5) (Fig.7)
b) Use + or – buttons to adjust the TIME (press and hold to change in 10 min
increments)
c) Use L or M buttons to adjust the TEMPERATURE (Fig.8)
d) Press PROG (Fig.2) to move to next preset time & temp (Event 2) (Fig.9)
e) Repeat steps b, c & d for programming Events 3, 4 5 & 6
For Days 6-7 (weekends)
Press PROG (Fig.2) to show 1
G
6-7) (Fig.10)
Repeat steps b, c and d above to programme time and temperatyure
G
events for the weekend
NB. Left hand LED will be lit when the Central Heating programme is running
TP9
User Instructions
Sat-Sun (5/2 day mode)
Event
20
1
16
2
19
3
16
4
21
5
16
6
st
pre-set time and temperature
st
pre-set time and temperature (Event 1 Days
Time
Temp°C
07.00
20
10.00
16
12.00
19
14.00
16
17.00
21
22.30
16
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
Fig.6
Fig.7
Fig.8
Fig.9
Fig.10

Advertisement

loading

Summary of Contents for Danfoss TP9

  • Page 1 Accepting the Factory Pre-settings Fig.3 The TP9 has pre-set times already programmed in for controlling the heating and hot water, which often suit most people (see Table below & Fig.12 over). To accept these settings press the PROG button until the time appears in the display and colon begins to flash - the unit is now in RUN mode (Fig.6).
  • Page 2: For 24 Hour Mode

    Fig.15 Returning to RUN mode Press PROG until the colon in the LCD display starts to flash (Fig.14) Temporary User Overrides The TP9 has several useful overrides which can be selected without affecting Fig.16 the thermostat programming • Temporary override of programmed temperature – press L or M (Fig.8)