Hide thumbs Also See for Vesuvius:

Advertisement

Quick Links

Information Technology Solutions
V
ESUVIUS OWNERS MANUAL
DRAFT COPY
V
ESUVIUS OWNERS MANUAL
M&V S.r.l.
Via L. Guerra, 9
80040 Cercola (NA)
Ph./Fax +39 0815552428
e-mail:
info@mevsrl.net
© M&V S.r.l.
Page 1 of 20
vesuvius userguide7 Aug 25 2014.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vesuvius and is the answer not in the manual?

Questions and answers

Summary of Contents for M&V S.r.l. Vesuvius

  • Page 1 Information Technology Solutions ESUVIUS OWNERS MANUAL DRAFT COPY ESUVIUS OWNERS MANUAL M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 1 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 2: Table Of Contents

    Electronic selection -Tanked or mains plumbed ......................... 5 Operation with Internal Tank ............................. 6 ..........................6 REPARING THE ESUVIUS FOR OPERATION Filling the Vesuvius for the first time..........................6 Flushing the Vesuvius before using ............................ 6 ..................... 7 ESCRIPTION OF THE MAJOR CONTROLS OF THE ESUVIUS Understanding the display &...
  • Page 3: Introduction

    Please lock to the 6:00 position or further for safe operation After having removed the packaging, make certain that the Vesuvius is not damaged in any way. If you have any doubts, do not use the Vesuvius and contact a professionally qualified person or your dealer.
  • Page 4: Unpacking The Vesuvius

    4 in total. Note: they are NOT on the top. The Vesuvius is secured to the base using rubber 2. The sides of the crate are secured by 4 transit feet with bots on the bottom that protrude...
  • Page 5: Attaching The Feet

    Mains Water Connection Routing the safety pressure release vent valve to the water tank, protects both you and the machines The Vesuvius is supplied ready for a mains water electronics if a fault causes any high pressure connection or internal tanked operation.
  • Page 6: Operation With Internal Tank

    The pump should not run during this process. Switch 2. Switch on the machine at the mains and the Vesuvius on, allow the service boiler to refill and once the firmware has loaded, turn the repeat this process.
  • Page 7: Description Of The Major Controls Of The Vesuvius

    Height adjustable Drip tray, feet removable, can M&V S.r.l. accept hose for Via L. Guerra, 9 80040 Cercola (NA) draining. Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 7 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 8 Illuminated O'ring seal plug when set for plumbed operation Mains water inlet M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 8 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 9: Understanding The Display & Programming Functions

    The display now is split into 3 Horizontal zones. functions The top zone shows brew pressure (when brew lever activated), Steam boiler temperature and The Vesuvius has a dot matrix display with much pressure. more information than a standard espresso machine and presented in a slightly different form.
  • Page 10: Main Menu Screen

    Enabling, greatly increases M&V S.r.l. capacity for a busy session Via L. Guerra, 9 and recommended if running 80040 Cercola (NA) eco steam mode Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 10 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 11: Eco Mode Explained

    If you don't use the daily on/off timers and want the machine to switch off if it's not being used M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 11 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 12 Does nothing, touch + to continue This The Vesuvius has an internal On/Off actually timer, with 2 on/off times each day, 7 shows E61 days per week. Touch. This allows the group lever machine to be ready in the morning, off...
  • Page 13: The Profile Screen

    The profile screen The profiling system is very easy to use and can The Vesuvius has 5 pressure profiles each with achieve results as simple or complex as you care to up to 7 phases. Touching the "home screen"...
  • Page 14: Programming Or Examining Pressure Profiles (Cont.)

    2 bar due to low flow rates from the pump. One of the reasons the Vesuvius always supplies the pump from it's internal tank, is to allow preinfusion pressures lower than mains line pressure (usually much higher than 2 bar).
  • Page 15: Profile Advice (Cont)

    The Vesuvius is able to use a grind much finer than repeatable control, well beyond that of any lever standard espresso machines and the less expensive machine.
  • Page 16: Vesuvius Specifications

    Pressure profiling 5 profiles can be saved each with up to 7 stages. Last shot protection The Vesuvius will always complete the last shot, even if water is low M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428...
  • Page 17: The Advanced Menu

    & to be when change the machine profiles is on M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 17 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 18 How many Does nothing minutes before important machine enters economy mode, if not used. M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 18 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 19 If you often walk away from the machine and miss the red low water warning on the display, you can reduce this value to 100 seconds. M&V S.r.l. Via L. Guerra, 9 80040 Cercola (NA) Ph./Fax +39 0815552428 e-mail: info@mevsrl.net © M&V S.r.l. Page 19 of 20 vesuvius userguide7 Aug 25 2014.doc...
  • Page 20: Maintenance

    Replace a heating element (with dealer • guidance) The Vesuvius should only be cleaned with non abrasive cleaners and a soft micro-fibre (recommended), cloth In the event of any abnormal operation or problem with the display or main computer: Switch the machine off and unplug it.

Table of Contents