Lamps must be replaced after 12 months of operation to ensure proper
disinfection of your water.
Clean quartz sleeve and UV sensor (if equipped) frequently for optimum performance.
Lamp replacement record:
1 st: _____________________________
2nd: _____________________________
3 rd: _____________________________
4th: _____________________________
5th: _____________________________
Head Office (Canada)
United Kingdom
3020 Gore Road
5 De Salis Crt.
London, Ontario
Hampton Lovett, Droitwich
Canada N5V 4T7
WR9 0QE England
Tel: (519) 457-3400
Tel: 44-1-905-771117
Fax: (519) 457-3030
Fax: 44-1-905-772270
F or
Pro15
602729
6th: _____________________________
7th: _____________________________
8th: _____________________________
9th: _____________________________
10th: _____________________________
www.trojanuvmax.com
DO NOT REMOVE FROM UNIT
CRITICAL OPERATING INFORMATION INSIDE
See back cover for vital records.

Advertisement

Table of Contents
loading

Summary of Contents for Trojan Technologies Trojan UV Max

  • Page 1 Installation performed by: ___________________________________________________________________________________________________________________ Date of installation: _______________________________________________________________________________________________________________________________ For service and lamp orders, call your installer at: __________________________________________________________________________________ or call Trojan Technologies Inc. at (519) 457-3400 Model installed: (circle model) E or F or or D Pro7 Pro15 Lamp part...
  • Page 2: Specifications

    Product Specifications SAFETY MODEL Pro7 Pro15 Flow Rates 0-3 GPM* 2-5 GPM* 5-14 GPM* 5-14 GPM* 8-28 GPM* 13-47 GPM* 8.2 GPM*** 17.8 GPM*** 0-11 LPM 7-19 LPM 19-53 LPM 19-53 LPM 30-106 LPM 49-178 LPM 31 LPM 67.4 LPM Audible/Visual Lamp Attention! Failure Alarm...
  • Page 3: Troubleshooting

    Troubleshooting - Plus and Pro Models Thank you. SITUATION POSSIBLE CAUSE POSSIBLE SOLUTION By purchasing the TrojanUVMax™ system, you have taken the first step to providing safe Elapsed Time Meter reads A3. System in high temperature This is not an alarm condition but only drinking water for you and your family.
  • Page 4: Troubleshooting

    5. Do not use the system for other than intended use. The use of attachments or accessories not recommended meter month is >12 and is flashing. or sold by Trojan Technologies may cause an unsafe condition and/or reduce disinfection performance. Indicator light glows red and is flashing. Alarm is sounding.
  • Page 5: Troubleshooting

    ELECTRICAL SAFETY Troubleshooting TrojanUVMax Troubleshooting for all Models GROUNDING SITUATION POSSIBLE CAUSE POSSIBLE SOLUTION Indicator light does NOT glow Unit is unplugged Plug unit into AC power outlet This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least and alarm does NOT sound No power at AC power outlet Replace fuse or reset breaker...
  • Page 6 Parts Included in the TrojanUVMax™ System This warranty is also subject to the outlined in the applicable One-Year Limited Warranty for Lamps, Sleeves, and conditions and limitations outlined under Owner’s Manual. UV sensors the heading “General Conditions and The limited warranties described Limitations”.
  • Page 7 Trojan Technologies Inc. the dealer from whom you Five-Year Limited WATER QUALITY PARAMETERS Limited Warranty purchased your Trojan product Warranty for Structural, These are recommended levels, for use as a guideline for pre-treatment requirements. (“the source dealer”), as well as a...
  • Page 8 INSTALLATION CLEANING THE QUARTZ SLEEVE Note: If the sleeve requires Note: Do not attempt to tighten, 1. To protect your power supply, you MODELS D, E, F, Pro7 and Pro15 INSTALLATION cleaning, the UV sensor will likely loosen, or open the sealed UV must use a surge protector.
  • Page 9 UV SENSOR INSTALLATION AND REMOVAL MODEL A 120V INSTALLATION To operate properly, the Plus and Pro to assembly. Insert the UV sensor into the port distribution lines between the UV series systems require that a UV sensor be in the reactor. Screw the brass nut on finger Clearance Equal to Reactor Length for Lamp Removal system and your water outlets must correctly installed.
  • Page 10: Elapsed Time Meter

    OPERATION The lamp must be replaced after 12 The 230V version of Unit A is not Audible Alarm months of operation. Failure to equipped with an audible alarm. During normal operation no sound replace the lamp will reduce the is emitted. If you experience either or both disinfection strength of the •...
  • Page 11: Alarm Postpone Button

    6. Reconnect the power supply and check that the LED is green. The The Elapsed Time Meter also period, it will go into alarm Dry Contacts alarm may sound until the lamp indicates the source of the problem again, the LED will turn solid red, This feature provides switching for operates properly.
  • Page 12: Lamp Replacement/Sleeve Cleaning

    INSTALLATION OR SERVICE position, place a screwdriver the lock nut provided onto 7. To remove the lamp from its REPLACEMENT OF UV sleeve (Figure 5), use a glove or shaft in one of the slots in the the ground stud to secure the AND MAINTENANCE LAMP/SLEEVE top of the lamp end and an...

Table of Contents