Download Print this page
Galanz AUS-12H53R150P Owner's Manual

Galanz AUS-12H53R150P Owner's Manual

Split wall mounted type

Advertisement

SPLIT WALL MOUNTED TYPE
Thank you for choosing our Air Conditioner. Please read this OWNER'S
MANUAL carefully prior to use and keep it for further reference.
AIR CONDITIONERS OWNER'S MANUAL
AUS-12H53R150P
AUS-18H53R120C

Advertisement

loading

Summary of Contents for Galanz AUS-12H53R150P

  • Page 1 SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL AUS-12H53R150P AUS-18H53R120C Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference.
  • Page 2: Table Of Contents

    CONTENTS Contents Safety Precaution Name of Parts Service and Maintenance Trouble Shooting Performance Parameters Remote Controller...
  • Page 3: Safety Precaution

    SAFETY PRECAUTION Read and understand thoroughly this safety awareness before use. The items indicated here are very important safety precautions, which must be followed. The following pictures are presented just for the purpose of illustration. As for some models whose cooling capacity is above 4600W(17000BTU/h), their power cables do not have a plug, a circuit breaker must be built in supply circuit.
  • Page 4 SAFETY PRECAUTION WARNING Do not use these stuffs for cleaning: chemical solvent, insecticide, inflammable spraying materials which will damage the appearance of air conditioner. Do not sprinkle water directly on the indoor unit. Close doors and windows (preferably use a curtain) while operating air conditioner for a long time, if room air is quite turbid, you could open the door and window for a moment to get some fresh air outside.
  • Page 5: Name Of Parts

    NAME OF PARTS 1.OUTDOOR UNIT AND INDOOR UNIT Filter Front panel Air inlet Display Air quality indicator lamp Deflector Left / Right deflector (Manual operation) Air inlet Connecting pipe Drain hose Air outlet Drain opening NOTICE Appearance of the indoor unit and outdoor unit may differ with some models. 2.DISPLAY MODELS This illustration generalizes all the displays for the models included in this manual book.
  • Page 6 NAME OF PARTS Sleep indicator COOL MODE lamp indicator lamp POWER COOL WARM SLEEP TIMER Timer indicator Run indicator HEAT PUMP MODE lamp lamp indicator lamp 3.EMERGENCY OPERATION SWITCH In case the batteries in the remote controller are wore out, or remote controller is at fault, use Emergency operation switch ( ...
  • Page 7: Service And Maintenance

    SERVICE AND MAINTENANCE Clean the front grille and air filters at least once in every two weeks. Before cleaning, be sure to stop the operation and turn off the breaker. Clean the front grille and air filters 1.Open the front grille by pulling the tabs on both sides and lift it up until it stops with a click. Pull out the air filters.
  • Page 8: Trouble Shooting

    TROUBLE SHOOTING The following cases are not troubles that will obstruct you in using please follow the fault analysis and continue using. Fault analysis! Is there a fault? Is it a power failure? Has the power plug fallen off? Air conditioner does Has the circuit breaker or fuse shut off not operate.
  • Page 9 TROUBLE SHOOTING Is there a fault? Fault analysis The air conditioner is deicing and it takes Indoor unit fan stops 10 minutes at most.( It freezes when during heating. outdoor temperature is low and humidity is high). It automatically resumes operation about 10 minutes later.
  • Page 10: Performance Parameters

    PERFORMANCE PARAMETERS Model AUS-18H53R120C AUS-12H53R150P Power 220-240V~50Hz Rated cooling capacity(W) 3550 4800 3800 Rated heating capacity(W) 5200 Cool 1600 1050 Standard input Heat pump 1050 1730 power(W) Aux-heat Air flow volume(m /h) Dehumidifying capacity (L/h) Waterproof class IP20(INDOOR) IP24(OUTDOOR) Protection class...
  • Page 15 < < < < < < < < < < < < < <...
  • Page 16 < < < < < < < < < <...
  • Page 17 KGS-04...

This manual is also suitable for:

Aus-18h53r120c