Page 3
RT-1261A Ear and Forehead Thermometer READ THIS BEFORE USING The following basic safety precautions should always be taken. 1. Close supervision is necessary when the thermometer is used by, on, or near children, handicapped persons or invalids. 2. Use the thermometer only for the intended use described in this manual.
TABLE OF CONTENT Cautions and Warnings Restrictions of Use Introduction Highlighted Features Package Contents Thermometer Parts LCD Screen Replacing the Battery About Normal Body Temperature & Fever...
Page 5
RT-1261A Ear and Forehead Thermometer Using the Device As an Ear Thermometer Hints on Taking Ear Temperature As a Skin/Surface Scan Thermometer Recalling the Memory Viewing Results on a Personal Computer Care & Cleaning Fever Indicator Troubleshooting Specifications Symbol Information...
Cautions and Warnings As with any thermometer, proper technique is crucial to obtaining accurate temperature readings. Please read this manual thoroughly and carefully before using. Always store the thermometer in a cool and dry place -20 ℃ to 60 ℃ (-4 ℉ to 140 ℉) and relative humidity less than 95%. Avoid direct sunlight.
RT-1261A Ear and Forehead Thermometer Restrictions of Use This thermometer is clinically proven to produce accurate temperature measurements. However, please be advised of the following: Accuracy cannot be ensured for a person who has deformity in the ear such that the thermometer probe cannot be properly inserted into the ear canal.
RT-1261A ear and forehead thermometer is an elegantly designed infrared thermometer meant for your family. Intended use nu-beca RT-1261A ear and forehead thermometer is intended for the intermittent measurement and monitoring of human body temperature from ear canal or skin/surface scan. The device is intended for use by people of all ages in the home.
RT-1261A Ear and Forehead Thermometer Highlighted Features Provide two body temperatures: ear or skin/surface scan. Fast and accurate: meets the accuracy requirement specified in ASTM E1965-98 and the EC directive 93/42/EEC. Non-contact measurement does not require lens filter, there by saving cost of replacement.
RT-1261A Ear and Forehead Thermometer Thermometer Parts Probe cover Night light On/Memory button Sticker Battery cover Data port Probe lens Probe Scan button...
Page 13
RT-1261A Ear and Forehead Thermometer Ear temperature indicator Skin/Surface temperature indicator Temperature scanning in progress Temperature reading Memory mode Record numbers Low bettery indicator Temperature unit Communication symbol...
Replacing the Battery The thermometer comes with two 1.5V AAA alkaline batteries. Replace them when “ ” appears. Please follow the steps to replace new batteries. Step 1 Remove the battery cover. Step 2 Place the new battery in the battery compartment and press it in until the battery is firmly secured.
Page 15
RT-1261A Ear and Forehead Thermometer Step 3 Reattach the battery cover. NOTE Although the thermometer works when “ ” appears, we still recommend that you change the battery to obtain an accurate result. Remove the battery if stored for a long period of time.
About Normal Body Temperature & Fever Body temperature can vary from one individual/person to next. It also varies by location on the body and time of day. Below shows the statistical normal ranges from different sites. Please keep in mind that temperatures measured from different sites, even at the same time, should not be directly compared.
RT-1261A Ear and Forehead Thermometer Using the Device As an Ear Thermometer Step 1 Remove the probe cover first. Step 2 Turn on the thermometer. Press and release the On / Memory button. When ready, the thermometer displays the last measurement.
Page 18
Step 4 Press and release the Scan button. Do not remove the thermometer until it beeps. Step 5 Read the result. “ ” is shown together with a temperature value. NOTE The thermometer does not require any costly lens filters. Turn off the thermometer by pressing On / Memory button twice.
RT-1261A Ear and Forehead Thermometer Hints on Taking Ear Temperture As with any other thermometer, you may observe slight variations in consecutive measurements. It is recommended that you take 3 temperature readings and use the highest one for the following situations: Infants younger than 3 months old.
As a Skin/Surface Scan Thermometer Step 1 Make sure the probe cover is capped. Step 2 Turn on the thermometer. Press and release the On / Memory button. The thermometer displays the last measurement. Step 3 Put the probe on the temple. Press and hold the Scan button.
Page 21
RT-1261A Ear and Forehead Thermometer Step 4 Read the result. Release the button and read the result. “ ” is shown together with a temperature value and beeps. NOTE As the skin/surface scan temperature is likely to be affected by sweat, oil and the surroundings, the reading shall be taken as a reference only.
Recalling the Memory Your thermometer stores 10 most recent readings. Step 1 Be sure the thermometer is OFF before recalling this memory. Step 2 Press the On / Memory button to turn on the thermometer. Step 3 Press the On / Memory button for 3 seconds to enter memory mode.
Page 23
RT-1261A Ear and Forehead Thermometer Step 4 Exit the memory. Press the Scan button and LCD will show latest results with flashing “ ” . Then press On / Memory button twice to exit the memory.
RT-1261A Ear and Forehead Thermometer Care & Cleaning Keep the probe clean, as earwax and grease build up may affect the measurement. To clean the probe lens, wipe it gently with an 70% alcohol swab or soft cloth moistened with 70% alcohol.
Troubleshooting The table below shows problems you may encounter. All error messages below would be shown together with orange backlight. Please follow “what to do” to resolve problems. If the problem still exists, please call your local dealer for help. Message What it means What to do...
Symbol Information Symbol Referent Consult instructions for use Keep away from sunlight Keep dry Temperature limitation Date of manufacture Manufacturer Serial number Caution, consult accompanying documents Authorized representative in the European Community CE mark Type BF equipment Do not use if package is damaged.
RT-1261A Ear and Forehead Thermometer Warranty nu-beca warrants this product to be free of defects in workmanship and materials for a period of ONE year from the date of purchase. During the warranty period, if this product is found to be defective, you may bring it together with the purchase receipt and Warranty Certificate on a carry-in basis to nu-beca’s office...
Need help?
Do you have a question about the RT-1261A and is the answer not in the manual?
Questions and answers