CAUTIONS & WARNINGS As with any t hermometer, proper technique i s crucial to getting accurate temperature readings. Please read this manual thoroughly and carefully before using. Always store the thermometer in a cool and dry place: temperatures between -20°C to 50°C (-4°F to 122°F) relative humidity less than 95%.
RESTRICTIONS OF USE This t hermometer is c linically proven to produce accu- rate temperature measurement s ; however, please be advised of following situations: The accuracy can not be ensured for a person who has deformity in t he ear such t hat t he t hermometer probe cannot be properly inserted into the ear canal.
Page 7
INTRODUCTION Thank you for choosing nu-beca RT-1112 Ear/Forehead Infrared Thermometer. This innovative medical t h e r m o m e t e r r e l i e s o n a d v a n c e d i n f r a r e d ( I R ) technology to measure temperature instantly and accurately through two convenient sites, the ear canal and the surface of the skin over the temple.
HIGHLIGHTED FEATURES Provide two body temperatures: ear or forehead. Fast and accurate: meet the accuracy requirement specified in ASTM E1965-98 and the EC directive 93/42 /EEC. does not require Non-contact measurement t hat lens filter, there by saving cost of replacement. Clock and room temperature inter-display.
SETTING THE THERMOMETER You will need t o set time and unit for first-time use or after replacing the battery. Set button S tep1 Press the Set Button. " " and the flashing hour appear first. S tep2 Set hour&minute Press the On/Scan button to select the “...
Page 14
Body temperature can vary from one person to next. It also varies by location on the body and time of day. Below shows the statistical normal ranges from different sites. Please keep in mind that temperatures measured from different sites, even at the same time, should not be directly compared.
Page 16
Hints on Taking Ear Temperature 1 .As with any type of thermometer, you may observe slight variations in consecutive measurements. It is recommended that you take 3 temperature readings and use the highest one for the following situations: Infants younger than 3 months old. Children younger than 3 years old and have a compromised immune system and t he presence/ absence of fever is critical.
Page 17
Step2 Press and hold the On/Scan button. Put the probe on the temple. Make sure the probe is flat on the temple, not at an angle. Flat NOTE As the forehead temperature is likely to be affected by sweat, oil and t he surroundings, the reading shall be taken as a reference only.
TURNING OFF THE DEVICE After measurements, t he meter will back to its initial mode after unused over 30 seconds. That is, if the meter is started from the OFF mode, it will be automatically off after measurements. Likewise, if the meter is started from the CLOCK/RT mode, it will be back to that mode after measurements.
Page 20
RECALLING THE MEMORY Your thermometer stores 20 recent readings in the memory. Be sure the thermometer is in either "OFF" or "CLOCK/RT" mode before recall. Step1 Press the M button to enter the memory. Step2 Press the M button to review the result.
CARE & CLEANING Keep t he probe clean, as build-up of ear wax and grease may affect the measurement. The probe is splash-proof. Please wipe with a clean dry cloth or dampened with 70% alcohol. The body of the thermometer is not water-resistant. Please never put the thermometer under a running tap or s ubmerge i t into water.
Page 22
Message What it means When the measurement is below 38°C(100.4°F), is shown together with the result. When the measurement is equal or over 38°C(100.4°F), Hi is shown together with the result.
Page 23
Room temperature is Put the thermometer under below 10°C. operating temperature range of 10°C to 40°C(50°F to 104°F). Room temperature is Put the thermometer under above 40°C. operating temperature range of 10°C to 40°C(50°F to 104°F). Please put the thermometer Problem with the under operating temperature thermometer.
SPECIFICATIONS Model no. RT-1112 Dimensions 106.3mm (L) x 32.1mm (W) x 35.2mm (H) Weight Displayed temperature range 0°C to 50°C(32°F to 122°F) 0.1°C/0.1°F Display resolution Meet the accuracy requirement specified in ASTM E1965-98 ±0.2°C(±0.4°F) for the range of 36.0°C Accuracy to 39.0°C (96.8°F to 102.2°F) ±0.3°C(±0.5°F) from 34 to 35.9°C and from 39.1 to 42.2°C...
SYMBOL INFORMATION Symbol Referent Consult instructions for use Keep away from sunlight Keep dry Temperature limitation Date of manufacture Manufacturer Serial number Caution, consult accompanying documents Authorized representative in the European Community CE mark Type BF equipment Do not use if package is damaged.
WARRANTY 1 . nu-beca & maxcellent co. (“nu-beca”) warrants this product to be free of defects in workmanship and materials for a period of ONE year from the date of purchase. 2 .During the warranty period, if this product is found to be defective, you may bring it together with the purchase receipt and Warranty Certificate on a carry-in basis to nu-beca office during normal business hours for warranty service.
Need help?
Do you have a question about the RT1112 and is the answer not in the manual?
Questions and answers