System8.6 Connections Provides a description of S8.6 system connections to included connections made with an ELAN System Precision Panel (SPP) and direct connections from the S8.6 to all other components. Troubleshooting Provides troubleshooting tables to help fix common discrepancies that may be associated with the S8.6.
Page 6
S8.6AVP Multi-Room A/V Controller A1240 12-Channel Power Amplifier More of a Good Thing ELAN’s proven analog amplifier technology is now available in a 12-channel design with a true 40 watts per channel. Feature-Packed The A1240 is loaded with the features most-asked-for by today’s Custom Installers, providing them with the flexibility needed to configure the perfect multi-room system.
The S8.6 Controller is an eight source, six zone controller with on-board composite video switching. Up to four System8.6AVP Controllers can be linked for a total of twenty-four zones. Controllable by IR or Serial commands, this unit works with ELAN VIA! ®...
Source-Specific IR Routing/ALL Port • 8 source-specific IR Output ports • 1 IR ‘ALL’ Output port Full ELAN Control Capability • Use with any ELAN keypad, touchpad, or LCD touch panel. • IR or RS-232 Control • Uses VIA! ®...
The Source IR Expansion Ports ( are used to connect multiple S8.6 chassis (see Figure 1- 10). These ports allow for sharing of IR between up to four units. NOTE: Multi-Chassis systems require the use of ELAN’s S12XK Expansion Kit. SOURCE IR OUTPUTS...
MOH OUT Figure 1-12. MOH OUT (Music-On-Hold Output) Page Audio Input/Output (PG IN/PG OUT) PG IN and PG OUT connections allow system-wide paging when utilized with ELAN’s COM2 Communications Controller ( . PG IN connects from the COM2 Communications Controller.
Figure 1-21. Source IR Outputs VIA!NET IN/OUT The VIA!NET IN and OUT Ports ( connect auxiliary S8.6 chassis and allows VIA!Net Port communication with other ELAN components such as the V883 Component Video Matrix Switcher (see Figure 1-22). VIA!NET IN VIA!NET OUT...
S8.6AVP Multi-Room Controller ELAN HOME SYSTEMS Table 2-1displays the ELAN pre-wiring recommendations for connections to the System8.6 Table 2-1 ELAN Pre-Wiring Recommendations Item Description VIA! Touch Panels Cat-5 network cable 16-18 AWG 2 conductor wire (On runs greater than 100 feet) RG-6 or RG-59 Coaxial cable Olé...
If using ELAN electronic volume controls, system and source control is possible using a hand- held remote control. This application uses two pairs of amp channels from the external ampli- fier.
Although the sub-zone has indepen- dent control of volume, it always shares the same source with the main zone. If using an ELAN electronic volume control in the sub-zone, system and source control is possible using a hand-held remote control.
System8.6 Connections SPP System Precision Panel The SPP System Precision Panel is designed to be the connectivity solution for all ELAN S Series Multi-Room Controllers. The rear panel of the SPP features a neatly laid out array of all the 110 punch-downs necessary to ensure quick, reliable connection of keypads, touch pan- els, touchpads, Sense Inputs and Triggers in every zone.
The S8.6 is designed to work flawlessly with ELAN VIA! Touch Panels. VIA! Touch Panels require ELAN 16 Volt DC power supplies. Use the PWR10 16V/10A power supply to power up to ten VIA! Touch Panels. Use the PWR4 16V/4A power supply to power up to 4 VIA! Touch Panels.
Z•Pad Connections “C” Punchdown Locations It is possible to use ELAN Z•Pad keypads as zone controllers in an S8.6-based system. These keypads will control IR sources and S8.6 Controller function, but they WILL NOT receive RS- 485 status feedback. This means that source selection status, shared source status, etc. will not be available to these keypads.
The Sense Trigger Inputs of the S8.6 are primarily for use with VIA! Touch Panels and Olé Touchpads. An ELAN™SENSE Sensor can be connected that will cause VIA! Touch Panels and Olé Touchpads to execute IR or serial commands. Use VIA!Tools setup software to pro- gram Trigger Input functionality.
Use the LINK IN and LINK OUT RJ-45 connectors to link multiple S8.6 chassis and multiple SPP Precision Panels. Use an ELAN C4545 RJ-45 to RJ-45 Interconnect cable from the LINK IN jack of the first SPP Panel to the LINK IN jack of the second SPP Panel and so on.
Figure 3-17. Internal/External Voltage Switch ZNET/VNET Switch The ZNET-VNET switch selects between systems based on ELAN’s ZNET (S6 and S12 Multi- Room Controllers) and VNET (S8.6 ). This switch will always be in the VNET position when installing the SPP with the S8.6 Controller.
Precision Panel’s TO SENSE INPUTS jacks and the S8.6 Controller’s ELAN SENSE INPUTS jacks. Utilize VIA!TOOLS Setup Software to create IR or serial com- mand strings for automated functions. See the VIA!TOOLS Help file for additional information about programming Sense Inputs.
S8.6AVP MULTI-ROOM CONTROLLER SS/SC4 Connection Use the SS/SC4 RJ-45 connector to integrate an ELAN SS1 System Station or SC-4 System Controller to the S8.6 Multi-Room Controller in order to facilitate integration of RS-232 con- trolled systems such as security, lighting or HVAC. Use an ELAN C4545 RJ-45 Interconnect Cable for this purpose.
ELAN PWR1 16VDC/1A power supply for one VIA! Touch Panels. Use an ELAN PWR4 16VDC/ 4A power supply for up to four VIA! Touch Panels. Use an ELAN PWR10 16VDC/10A power supply for five-to-ten VIA! Touch Panels. It is also possible to connect up to 66 Olé Touchpads using the same 16VDC power supplies.
ELANSENSE Sensors directly to the S8.6, simply plug the 3.5 mm stereo plug of the Sensor into the desired ELAN SENSE INPUT. If long runs are required, the 3.5 mm stereo interconnect cable must be cut off and the cable extended using Cat-5. Utilize VIA!TOOLS Setup Software to create IR or serial command strings for automated functions.
For simplicity, all eight wires can be connected straight through. Figure 3-29. Olé Touchpad Connections (No SPP) Keypad Connections ELAN keypads require IR, 12 Volts DC, and Ground to function. Make these connections as shown below. Multiple keypads in the same zone require parallel connections. •...
This makes it possible to use identical source compo- nents and still have the capability of separate control. For ELAN multi-output sources such as VIA!dj or DTNR, VIA!TOOLS setup software will automatically route IR out of each IR port that the source is assigned to.
The ALL IR OUT port is also useful when controlling several- non-identical sources. For really large installations, an ALL IR OUT port can be routed to an IR Distribution Block (such as ELAN’s IRD4) and sent to several sources. Figure 3-34. All IR OUT Port Connections Audio/Video Connections There are eight Audio SOURCE INPUTs and eight Audio LOOP OUTPUTS on the S8.6.
In advanced systems that require more than six composite video outputs (per chassis) to some or all of the S8.6’s zones, use an ELAN Z•880 Video Controller to switch up to eight sources to up to eight zones (or use up to three Z•880s to switch up to eight sources to up to twenty-four zones).
Advanced Video Switching-Component Video V883 Component Video Controller Use an ELAN V883 (or multiple V883s) to switch component video. Up to 8 sources can be switched to up to 32 locations using multiple V883s. Connect RCA audio patch cables from a source to the S8.6’s Source Audio Inputs.
Plug the 6-Pin DIN (round) connector into the SC-4’s ELAN RS-232 OUT port. Using the gen- der-changer, plug the other end of the serial cable into the ELAN RS-232 IN port on the S8.6. The SC-4 will always be connected to Chassis #1 in a multi-chassis system.
When controlling the S8.6 with ELAN’s SS1 System Station, use the DB-9 to DB-9 serial cable that is included with the SS1. Connect the cable from the SS1’s ELAN RS-232 port to the S8.6’s ELAN RS-232 IN port. The SS1 will always be connected to Chassis #1 in a multi-chas- sis system.
S8.6AVP MULTI-ROOM CONTROLLER COM2 Communications Controller Connections ELAN’s COM2 Communications Controller provides whole-house paging when used with the S8.6. The S8.6’s MOH OUT port provides Music On Hold to telephones connected to the COM2. The audio from Source 1 of the S8.6 is routed out of the MOH OUT port and into the COM2 as shown in Figure 3-48.
S8.6AVP MULTI-ROOM CONTROLLER Multi-Chassis Connections It is necessary to purchase and use ELAN’s S12XK Expansion Kit when installing more than one S8.6 chassis. One S12XK Kit must be used for each additional chassis. All required cables are included in the S12XK Kit. Figures 3-50 through 3-54 show all connections necessary when installing multiple S8.6 chassis.
Page 70
Figure 3-50. Multi-Chassis Source IR Expansion Port Connections VIA!NET IN/OUT Ports Use ELAN C4545 RJ-45 Interconnect Cables to connect The VIA!NET OUT port of Chassis #1 to the VIA!NET IN port on Chassis #2. Follow this pattern for additional chassis as shown in Figure 3-52.
Page 71
S8.6AVP MULTI-ROOM CONTROLLER ELAN RS-232 Ports Use the DB-9 connectors included in the S12XK Kit to connect the ELAN RS-232 PORTS as shown in Figure 3-53 if RS-232 is being used to control the S8.6 system. These connections are not necessary if controlling the S8.6 with IR. These connections are not required for RS- 232 devices that are connected to an ELAN SS1 System Station or SC-4 System Controller.
When mounting the S8.6 controller in an equipment rack, use the included rack mount brack- ets for secure mounting. To install the rack mount brackets onto the S8.6 AVP and into a standard 19" equipment rack: Place the bracket mount onto the side of theS8.6 chassis. (Figure 3-56).
Page 80
Cause/s In Chassis IR/RS-485 Connect Expansion Port OUT of Chassis #1 to Expansion #2-4 only; Expansion Port IN of Chassis 2, etc. using ELAN’s S12XK Expansion Kit. •WHM, Pag- ports not con- ing, Doorbell, nected or System Off do incorrectly not function connected.
Page 117
Hexadecimal 0x0D or Decimal 13 Unit 1-4 abcdefghijklmnop: Version can be variable length, 16 ASCII char maximum. Always begins with “&S86” even if command sent used the common system header of “&ELAN” Examples: • &S86,VER,1?<cr> Queries Unit 1. • &ELAN,VER,2?<cr> Queries Unit 2.
ELAN in writing, ELAN shall repair or replace the item at the company's option. This warranty shall not apply (a) to equipment not manu- factured by ELAN, (b) to equipment which shall have been installed by other than an ELAN authorized installer, (c) to...