Introduction
This is the GE Indoor/Outdoor PIR Motion Sensors Installation
Instructions for model numbers:
• 60-639-95R (indoor)
• 60-639-95R-OD (outdoor)
• 60-639-43-EUR (indoor, not investigated for use by UL)
• 60-639-43-ERT-OD (outdoor, not investigated for use by
UL)
Passive-infrared (PIR) motion sensors detect movement within a
specific area by sensing the infrared energy emitted from a body
as it moves across the sensor's field of view, causing a tempera-
ture change in the sensor's zones. When the sensor detects this
motion, it transmits an alarm signal to the control panel.
Use the indoor sensors to protect large areas and open floor plans
or as backup protection for door/window sensors.
Use the outdoor sensors to identify motion in a protected outdoor
area. Detected motion in this protected area can sound chimes or
turn on outside lights. Do not use the outdoor sensors for intru-
sion protection.
Features include:
• 35 by 40 ft. (10.7 x 12.2 m) coverage area for standard and
optional pet alley lenses;
• masking kit to block portions of the coverage area;
• three-minute transmitter lockout time after an alarm to
extend battery life;
• cover-activated tamper (an optional wall-activated tamper is
provided);
• supervisory signal transmitted every 64 minutes to the
control panel;
• sensor low battery reports (trouble) to the control panel; and
• field-selectable sensitivity options.
Indoor sensor installation
Use the following installation guidelines:
• If possible, mount the sensor within 100 ft. (30.5 m) of the
panel. While the transmitter may have a range of 500 ft.
(152.4 m) or more out in the open, the environment at the
installation site can have a significant effect on transmitter
range.
• Position the sensor to protect an area where an intruder is
most likely to walk across the detection pattern. (Figure 1).
Figure 1. Overhead detection pattern
Indoor/Outdoor PIR Motion Sensors
Installation Instructions
• Mount the sensor between 5 and 8 ft. (1.5 and 2.4 m) from
the floor (Figure 2). We recommend a height of 7.5 ft. (2.3
m). Higher mounting provides better range, and lower
mounting provides better protection close to the sensor. See
Pet alley lens
Figure 2. Detection pattern
Top view
20 ft.
6 m
10 ft.
3 m
0 ft.
0 m
10 ft.
3 m
20 ft.
6 m
Side view with mounting height of 7.5 ft. (2.3 m)
8 ft. (2.4 m)
4 ft. (1.2 m)
0 ft. (0 m)
Side view with mounting height of 5 ft. (1.5 m)
8 ft. (2.4 m)
4 ft. (1.2 m)
0 ft. (0 m)
Side view with pet alley lens and flush mount
8 ft. (2.4 m)
4 ft. (1.2 m)
0 ft. (0 m)
466-1534G • August 2006
Copyright © 2006, GE Security Inc.
on page 3.
5 ft.
15 ft.
25 ft.
1.5 m
4.5 m
7.5 m
5 ft.
15 ft.
25 ft.
1.5 m
4.5 m
7.5 m
5 ft.
15 ft.
25 ft.
1.5 m
4.5 m
7.5 m
5 ft.
15 ft.
25 ft.
1.5 m
4.5 m
7.5 m
35 ft.
10.5 m
35 ft.
10.5 m
35 ft.
10.5 m
35 ft.
10.5 m

Advertisement

loading

Summary of Contents for GE 60-639-95R

  • Page 1 • Mount the sensor between 5 and 8 ft. (1.5 and 2.4 m) from the floor (Figure 2). We recommend a height of 7.5 ft. (2.3 This is the GE Indoor/Outdoor PIR Motion Sensors Installation m). Higher mounting provides better range, and lower Instructions for model numbers: mounting provides better protection close to the sensor.
  • Page 2 Indoor/Outdoor PIR Motion Sensors Installation Instructions • Mount the sensor on a rigid surface that is free of vibrations. To mount the sensor, do the following: • Do not aim the sensor at windows, fireplaces, air condi- To remove the mounting plate, depress the button on the top tioners, area heaters, or forced air heating vents.
  • Page 3: Lens Replacement

    Sensitivity settings Lens replacement To change the lens, do the following: The sensor is set to standard sensitivity at the factory. This sensi- Depress the button on the top of the sensor and pull the tivity is preferred for most applications and provides the best sensor from the mounting plate.
  • Page 4: Outdoor Sensor Installation

    Indoor/Outdoor PIR Motion Sensors Installation Instructions Outdoor sensor installation Testing Use the following guidelines for outdoor installations: Testing the sensor includes a walk test, an environment test, and a final test with the control panel. • Use the outdoor sensors for outdoor applications with a temperature of 10 to 120°F (12 to 49°C).
  • Page 5: Maintenance

    Maintenance Troubleshooting Test the sensor at least once a year to verify proper range and If the system doesn’t respond correctly when the sensor is acti- coverage. Instruct the end user to put the sensor in walk test vated, follow these guidelines: mode and walk through the end of the coverage pattern to verify •...
  • Page 6: Specifications

    Arden Hills, MN 55112 Outdoor sensor 10 to 120°F (12 to 49°C) Storage temperature -30 to 140°F (-34 to 60°C) EU representative: GE Security, B.V. Kelvinstraat 7 Maximum relative humidity 90% relative humidity noncondensing 6003 DH Weert Dimensions (L x W x H) 2.9 x 2.4 x 1.9 in.