6000 Series PIR
Model PI6000 - with 30 lb. pet immunity
Model 6000 - with high density (HD) performance lens
Installation Instructions
Back housing
Circuit board
Description
The 6000 Series Passive Infrared Detectors are designed for use in
residential applications. These detectors utilize dual pyroelectric
sensors with jumper selectable pulse count (two- or three-pulse mode).
Advanced signal processing provides high immunity to false trips - RFI,
lightning, vibration, and rapid temperature changes.
An interchangeable, opaque Fresnel lens blocks visible light and
provides the ability to select the best coverage pattern for the site. The
lens is part of a sealed optic enclosure which isolates the pyroelectric
sensor from drafts and insects, common sources of false trips.
The 6000 series comes with a closed loop alarm contact and a closed
loop tamper switch.
Selecting a Location
.
Mount the detector at a height of 7 to 9 feet (2.1 to 2.7m) . See
Mounting Height Settings.
Mount the detector either flat on the wall or in a corner and at
least 3/8" (0.95cm) from the ceiling. See Figure 2.
Do not locate the detector where it may be exposed to false
alarm sources, such as:
- heat sources in the field of view
- direct or reflected sunlight
- strong air drafts (fans, air conditioners, etc.) on unit
6000 Series PIR
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Shield
Figure 1. Detector (Exploded)
Lens
Front housing
Flat Wall
3/8"
0.95cm
Figure 2. Mounting
Do not aim the detector at windows or glass doors.
Mount the detector on a rigid, vibration-free surface.
Do not locate the detector on a surface exposed to moisture.
Do not locate the detector where the ambient temperature is
below 14°F (-10°C) or above 122°F (50°C).
PIRs require a clear line of sight. Inform end-users not to block the
coverage pattern with inventory, furniture, decorations etc.
Note
Use a screwdriver to undo the
latch on the bottom of the detector.
Corner
3/8"
0.95cm

Advertisement

loading

Summary of Contents for GE PI6000 - Sentrol Motion Detector

  • Page 1 6000 Series PIR Model PI6000 - with 30 lb. pet immunity Model 6000 - with high density (HD) performance lens Installation Instructions Lens Front housing Back housing Circuit board Note Use a screwdriver to undo the Shield latch on the bottom of the detector. Figure 1.
  • Page 2: Back Housing/Mounting Height Settings

    Primary wire entry Wire entry hole for Primary mounting hole hole for corner surface wire runs for flat wall mounting Jumpers Locking tab J3 J4 J4 LED Mounting Center wire holes for entry hole corner mounting Cable strain relief Power In 10 to 16 VDC +       –     NC  COM T       T...
  • Page 3 Masking PI6000 Pet Immune Lens Unsnap the shield from the front cover by grasping the edge of the Top View two tabs holding the shield in place and gently pulling the shield away 12.2m from the front housing. Remove the lens from the front housing. Make sure fingers are clean.
  • Page 4 40’ x 40’ PIR with 30 lb Pet Immune Lens, closed loop, with tamper C-UL US 6000 35’ x 35’ PIR with High Density Lens, closed loop, with tamper C-UL US GE Security USA & Canada: 800-547-2556 12345 SW Leveton Drive Technical Service: 800-648-7424 Tualatin, OR 97062...

This manual is also suitable for:

6000