LGM Module Driver

Parameter Page

Function Block Type: LGM (LGM Module Driver)
Name SiteGate-232
ID ID14
Tele NB
Power Up Delay 0
(sec)
Update Time
0:00 (mm:ss)
BACnet Device Parameters:
Use default device object name? Y
Use default device object ID?
APDU Timeout ............. 3000
Number of APDU Retries ... 0
GFB performance tuning:
=======================
Time slice per GFB = 5000 milliseconds.
CMnet Parameters:
General:
Generate a "Dead Module" alarm after 10 minutes of no communications
with a control module.
Zero compression enabled? YES
Output character pacing? (reduces throughput by 50%) NO
Delay before sending all replies (20 msec minimum) = 20
Interpacket delay .............. (20 msec minimum) = 20
Alternate interpacket delay .... (40 msec minimum) = 40
CMnet Tuning Parameters: (Tech Support Only)
Time to wait for '?' before attempting intrusive grab = 500
Maximum number of intrusive grab attempts per request = 3
Grab Silence Time
Time to hold the token when the token wraps around
Time to wait for each module to acknowledge the token = 500
Maximum online time per successful grab
Maximum monitor time per monitor request =
Console Port #1 Parameters:
Modem installed on this console port = NO
Modem control parameters:
Modem Reset ATV0E0Q0S0=1S7=60
Dial Prefix ATDT
Phone Number
Use This Number? NO
If not connected, and with no alarms pending delivery, reset modem
every
5:00 (mm:ss).
If connected, but no activity has been detected for 20:00 (mm:ss),
hang up and reset modem.
After dialing, wait
After unsuccessful alarm delivery, wait
trying again.
Escape (+++) guard time 1000 msec.
Post hangup delay
Reset time (DTR low)
Post DTR high delay
Post reset string delay 1000 msec.
Console Port #2 Parameters:
Modem installed on this console port = NO
Modem control parameters:
Modem Reset ATV0E0Q0S0=1S7=60
Dial Prefix ATDT
Phone Number
Use This Number? NO
Rev. (08-JULY-98)
Line 1
LG 2
All Options Y
Demand Controller Address 0
Device Name =
Y
Device ID
(milliseconds)
=
(NO = use number from
Note: the minimum value for this is 5:00.
2:00 (mm:ss) for connection before hanging up.
5:00 (mm:ss) before
1000 msec.
1000 msec.
500
msec.
(NO = use number from
15
CM 1
FB 15
Flags —
Type 67
Ver 1
,0
= (device object, 0)
msec.
msec.
msec.
msec.
= 600
msec.
= 1
seconds
msec.
0:50 (mm:ss)
5:00 (mm:ss)
SETGCM )
SETGCM )