Specifications at 240 volts, 50 Hz and an ambient of 23 +/- 2
Supply Voltage
Wattage Rating
• Auto Heat Up for Switch On
• The unit shall detect the thermo block temperature and set different
heating rates for even temperature distribution while minimising the
heat up times.
• The maximum heat up time shall be no more than 1 minute 30
seconds.
 Note: Maximum heat up time is the period taken for a unit to reach
ready mode from a room and unit temperature of 25
is when the Power LED is Green Illuminated.
• All LEDs, push buttons and control knobs shall perform accordingly to their
function. Refer to figure 1 for further information.
On
Off
Steam
• The push buttons shall not be jammed or wedged in position.
• The LED's shall illuminate accordingly to their function.
• Control Knobs shall not be jammed or wedged in position.
• During thermal heat up mode, Power dual coloured LED shall flash in green and
while rest of the LEDs shall be off. Refer to figure 2 for further information.
Power
• When either 1 of the 2 heating blocks reaches ready temperature, the unit
shall go into ready mode as illustrated by the LED pattern below shown in
Figure 3.
EM6910 Café Series Espresso Machine

PERFORMANCE

230 - 240V AC 50Hz.
2400W-10% @ 240VAC
(2160W to 2400W)
Power
Manual
One Cup
Water Level
Figure 1
Manual
One Cup
Two Cups
Figure 2
Issue: A
0
:
o
C. Ready mode
Coffee
Two Cups
Program
Program