Projector Status Indicators

* Lamp Indicator, operation indicator and temperature indicator at the top of the projector show the user the operating status
of the projector.
Operation Indicator
Lamp Indicator
Temperature Indicator
10
Operation Indicator
Orange
Standby.
Green(flashing)
Lamp cooling until the lamp turn on.
Green
On operation. (Turn on the lamp)
Orange(flashing)
Projector lamp is cooling as power out (2 minutes)
Off
Power off.
Projector lamp is reaching the end of its life and needs
Red
to be replaced with a new lamp. (over 2000 hours)
The projector has trouble in the lamp or around it at
power-on. Retry Power On again later. If lamp indicator
Red(flashing)
is red (flashing) again, contact the service center.
Green(flashing)
The lamp cover is not closed.
This projector is in high temperature. Turn the power of
Orange
projector off and check the ventilator.
Red
The projector is turned off as its high temperature.
Power has turned off due to problem with the
Red (flashing)
internal cooling fan. Contact your service center.
Lamp Indicator
Temperature Indicator