SECTION 2 -

ELECTRICAL SUPPLY AND CONNECTION

Electrical ratings are as stated on the unit data plate. The listing in Table 1 is based on
standard UK specification at 230V. Wiring must be executed in accordance with the
regulations listed in this booklet.
WARNING: Each individual appliance must be earthed!
After completion of installation, the method of operation should be demonstrated to the
kitchen staff. The isolating switch location, for use in an emergency or during cleaning
should also be pointed out.
This model is designed to be connected to a single phase AC supply using the 2 metre
mains lead fitted as standard.
Wires are coloured in accordance with the following code and should be connected to the
plug as follows:
EARTH to terminal marked E
NEUTRAL to terminal marked N
LIVE to terminal marked L.
Units which receive power from a plug, adaptor or distribution board must be individually
protected by a fuse with an appropriate rating.
Any replacement supply cable must be 1.5mm², cord code designation 245 IEC 57
(CENELEC H05 RN-F).
For internal connection, outer sheathing must be stripped 140mm from the cable end. The
live and neutral conductors must be trimmed so that the Earth conductor is longer by 50mm.
Pass inlet cable through the rear panel cord grip and ensure that the cable is routed without
leaving excessive free length inside the appliance.