System Power Requirements - F5 ARX 6000 Hardware Installation Manual

6-slot chassis
Hide thumbs Also See for ARX 6000:
Table of Contents

Advertisement

Chapter 5
System Specifications
Component
Hardware module dimensions (SCM,
ASM, NSM)
Hardware module power
(SCM, ASM, NSM)
(See Table 5.2 for power
consumption information.)
Table 5.1 System and Module Specifications (Continued)

System Power Requirements

(
1
------------------------------------------------------------------------------------------------------------------------------------------------------------------- -
5 - 4
Specification
Height: 15.25 in. (38.74 cm)
Width: 1.75 in. (4.45 cm)
Depth: 20 in. (50.8 cm)
Input voltage: -48 Vdc
®
The ARX
6000 chassis uses one or two power supplies. When two power
supplies are installed, the power load is shared. The power supplies require a
20 A/220 Vac input cord, which is provided with the chassis. The AC outlet
to the switch must be properly grounded.
Table 5.2 lists the system (fan tray and modules) power consumption.
Component
System Control Module (SCM)
Network Services Module (NSM)
Adaptive Services Module (ASM)
Fan Tray (6 fans + fan controller)
Table 5.2 Module Power Consumption
The total power dissipated by the chassis is the sum of all of the above
divided by 0.88 (the power supply runs at 88% efficiency). Specifically,
×
)
(
×
SCMpwr
n
ASMpwr
+
Power (Watts)
Typical
160 W
125 W
210 W
105 W
)
(
×
m
NSM
pwr
+
0.88
Maximum
179 W
137 W
237 W
176 W
)
(
×
)
1
fans
+

Advertisement