Response
Response Data
NOTE: The ANT_SETTING and RX_GAIN may have to be modified to access some non-standard PICCs.

5.8 PICC Setting

To modify the PICC setting of the device, issue the following command:
ACR128 Escape Command
Modify PICC Setting
Table 16: PICC Setting Data Values
Data
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
To read the existing PICC setting of the device, issue the following command:
ACR128 Escape Command
Read PICC Setting
Response
Response Data
Use Tables 16 to format and interpret PICC Setting Data values.
NOTE: MOD_B1, COND_B1 ... RX_A2 may have to be modified to access some non-standard ISO14443
PICCs.
ACR128 API
Version 1.7
May 2008
ACR128 Dual Interface Smart Card Reader
E1
00
00
00
2A
Description
Default Value
MOD_B1
08
COND_B1
3F
RX_B1
FF
MOD_B2
08
COND_B2
34
RX_B2
FF
MOD_A1
06
COND_A1
3F
RX_A1
9F
MOD_A2
06
COND_A2
05
RX_A2
9F
2A
E1
00
00
00
04
06
Antenna
Setting
0C
Data [12 bytes]
00
0C
Data [12 bytes]
RX
TX
Gain
Mode
Page 20 of 36