Breakdown Self Diagnosis Function - Panasonic WH-SHF09F3E5 Service Manual

Air-to-water heatpump
Hide thumbs Also See for WH-SHF09F3E5:
Table of Contents

Advertisement

16.3

Breakdown Self Diagnosis Function

16.3.1 Self Diagnosis Function (Three Digits Alphanumeric Code)
When abnormality occur during operation, the system will stop operation, and OFF/ON control panel LED will
blink and error code will display on the control panel timer display LCD.
Even error code is reset by turning OFF power supply or by pressing ERROR RESET button, if the system
abnormality is still un-repaired, system will again stop operation, and OFF/ON control panel LED will again blink.
The error code will store in IC memory.
To check the error code
1
When an abnormality occurs, system will stop operation and OFF/ON control panel LED will blink.
2
Error code of the abnormality will display on the control panel timer display LCD.
3
To determine the abnormality description, the error code table needs to be referred.
To display past/last error code
1
Turn ON power supply.
2
Press and hold the CHECK button for more than 5 seconds to enter status mode.
3
Press the SEARCH DOWN/UP button to retrieve past/last error code.
4
Press the CANCEL button or wait 30 seconds to exit status mode.
To permanently delete error code from IC memory
1
Turn ON power supply.
2
Press and hold the ERROR RESET button for more than 8 seconds till a beep sound is heard.
ACTUAL
HEATER
hr
HEAT
BOOSTER
MON TUE WED THU FRI SAT SUN
°C
QUIET
ON
kwh
TANK
SETTING
OFF
hr
HEATER
STATUS
°C
FORCE
SERVICE
OPERATION
CANCEL
Button
ERROR
RESET
Button
84
CHECK Button
SEARCH
Downward/Upward
Button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-uh12fe5Wh-shf12f6e5Wh-uh09fe5

Table of Contents