4. Controller parameter and indication channels

4.1 Channel overview

Legend:
X
Corresponding channel is available.
X*
Corresponding channel is available if the
appropriate option is activated.
Please note:
S3 and S4 are only indicated in case of sensors
connected.
Channel
1
COL
x
COL1
COL2
TST
x
TSTL
TST1
TSTU
TST2
TFSB
TRET
S3
x
TRF
S4
n %
x
n1 %
n2 %
h P
x
h P1
h P2
kWh
MWh
ARR
1
DT 0
x
DT10
DT F
x
DT S
x
RIS
x
DT1F
DT1S
RIS1
S MX
x
S1MX
DT20
DT2F
DT2S
RIS2
S2MX
EM
x
EM1
ARR
2
3
4
5
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
4
5
2
3
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
SECTION III: SOLAR CONTROL SYSTEM
1
Corresponding channel is only available if the option
heat quantity measurement is activated (OHQM).
2
Corresponding channel is only available if the op-
tion heat quantity measurement is deactivated
(OHQM).
MEDT
The channel anti-freeze content (MED%) is only
shown if water or vacuum-antifreeze FSV
(MEDT 0 or 3) are not used as anti-freeze.
6
7
8
9
x
x
x
Temperature collector (1)
x
Temperature collector 1
x
Temperature collector 2
x
Temperature store 1
x
x
Temperature store (1) below
x
Temperature store 1 below
x
x
Temperature store (1) above
x
Temperature store 2 below
x
Temperature solid fuel boiler
x
Temperature heating circuit
Temperature sensor 3
Temperature return sensor
x
x
Temperature sensor 4
x
Pump speed relay (1)
x
x
x
Pump speed reley 1
x
x
x
Pump speed relay 2
x
Operating hours relay (1)
x
x
x
Operating hours relay 1
x
x
x
Operating hours relay 2
Heat quantity kWh
Heat quantity MWh
6
7
8
9
System
x
x
x
Switch-on temperature difference (1)
x
Switch-on temperature difference 1
x
x
x
Switch-off temperature difference (1)
x
x
x
Nominal temperature difference (1)
x
x
x
Increase (1)
x
Switch-off temperature difference 1
x
Nominal temperature difference 1
x
Increase 1
x
x
x
Maximum temperature store (1)
x
Maximum temperature store 1
x
Switch-on temperature difference 2
x
Switch-off temperature difference 2
x
Nominal temperature difference 2
x
Increase 2
x
Maximum temperature store 2
x
x
x
Emergency temperature collector (1)
x
Emergency temperature collector 1
Specification
Page
43
43
43
43
43
43
43
43
43
43
43
43
43
43
43
43
44
44
44
45
45
45
45
45
45
45
45
45
45
46
46
45
45
45
45
46
47
47
41 VELUX

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFF 200 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tff 300Tff 400 0201

Table of Contents

Save PDF