Line Period Csr - Basler L400k User Manual

Table of Contents

Advertisement

Configuring the Camera

Line Period CSR

Note: The line period can be set by writing a floating point value to the Absolute Line Period field
or by writing an integer value to the Raw Line Period field. Refer to Section
explanation of the difference between these two fields.
Register Base Address: 0x1600
Field Name: Register Status
Description: The integer value in this field indicates the status of this control register:
Field Name: Absolute Line Period
Description: Writing a floating point value to this field sets the line period in µs. For example, if the value
Field Name: Absolute Min
Description: Minimum allowed floating point value for the absolute line period setting.
Field Name: Absolute Max
Description: Maximum allowed floating point value for the absolute line period setting.
Field Name: Raw Line Period
Description: Writing an integer value to this field sets the line period.
4-16
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
in this field is set to 180.60, the line period would be 180.60 µs.
The minimum and maximum absolute line period settings vary depending on the camera
version and other settings (see Section 3.2). To determine the current minimum and max-
imum settings, check the entries in the Absolute Min and Absolute Max fields.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
See Section
3.4
for more information about the line period.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
The actual line period is equal to the integer value multiplied by 2/30 µs. For example, if the
value in this field is set to 1500 (0x0005DC), then:
Line Period = 1500 x (2/30) µs
Line Period = 100 µs
The 4 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the raw value
Byte 2 = Mid byte of the raw value
Byte 3 = High byte of the raw value
Byte 4 = Always 0x00 (not used)
The minimum and maximum raw line period settings vary depending on the camera ver-
sion and other settings (see Section 3.2). To determine the current minimum and maximum
settings, check the entries in the Raw Min and Raw Max fields.
See Section
3.4
for more information about the line period.
Draft
Offset: 0x0000
Offset: 0x0001
Offset: 0x0005
Offset: 0x0009
Offset: 0x000D
4.2.2.1
Size: 1 Byte
Type: Read only
Size: 4 Bytes Type: Read / Write
Size: 4 Bytes Type: Read only
Size: 4 Bytes Type: Read only
Size: 4 Bytes Type: Read / Write
BASLER L400
for an
k

Advertisement

Table of Contents
loading

Table of Contents