14 - Anti-code Reset
Each area can be programmed for Anti-code Reset following
an Intruder or Tamper alarm. Areas assigned to 'Anti-code
Reset' will respond as follows:
The assigned areas can be reset using the Anti-code as
well as an Engineer code
Areas not assigned to 'Anti-code Reset' can only be reset
using an Engineer code or User code.
!
Areas can only be assigned to 'Anti-code Reset' if they
are also assigned to 'Alarms Eng Reset'.
15 - ATS Path Faults
Areas assigned to 'ATS Path Faults' (ATS = Alarm
Transmission System) will respond as follows when an ATS
fault occurs.
All keypads will display 'ATS Path Fault'
All keypads and speakers assigned to the same area as
the 'ATS Path Fault' will generate a Service tone every 30
Seconds until the fault is acknowledged by the User
entering a valid code for that area
An assigned area can be armed, as long as 'Arm With No
ATS' is also assigned to that area (see option 16). However,
a warning will be given to indicate the problem
Areas not assigned to 'ATS Path Faults' will never be affected
by an ATS fault.
16 - Arm With No ATS
Areas assigned to 'Arm With No ATS' (ATS = Alarm
Transmission System) can be armed when an ATS fault
occurs in those areas (see option 15).
Areas not assigned to 'Arm With No ATS' can never be armed
when an ATS fault occurs in those areas (see option 15).
17 - AC Mains Fail
Areas assigned to 'AC Mains Fail' will respond as follows
when an AC mains failure occurs.
All keypads will display 'AC Mains Fail'
All keypads and speakers assigned to the same area as
the 'AC Mains Fail' will generate a Service tone every
minute until the fault is acknowledged by the User
entering a valid code for that area
An assigned area can be armed, as long as 'Arm With AC
Fail' is also assigned to that area (see option 18). However,
a warning will be given to indicate the problem
Areas not assigned to 'AC Mains Fail' will never be affected
by an AC mains failure.
18 - Arm with AC Fail
Areas assigned to 'Arm With AC Fail' can be armed when an AC
Mains fail occurs in those areas (see option 17).
Areas not assigned to 'Arm With AC Fail' can never be armed
when an AC Mains fail occurs in those areas (see option 17).
19 - Full Arm Coms
Areas assigned to 'Full Arm Coms' will respond as follows:
If the selected area is fully armed and an Intruder alarm
occurs in that area, Intruder alarm events (for that area) are
reported to the Alarm Receiving Centre after any
programmed 'Digi delay' has expired
Areas not assigned to 'Full Arm Coms' will never report Intruder
alarm events to the Alarm Receiving Centre when they are fully
armed.
INS176
20 - Part Arm Coms
Areas assigned to 'Part Arm Coms' will respond as follows:
If an assigned area is part armed and an Intruder alarm
occurs in that area, Intruder alarm events (for that area)
are reported to the Alarm Receiving Centre after any
programmed 'Digi delay' has expired
Areas not assigned to 'Part Arm Coms' will never report
Intruder alarm events to the Alarm Receiving Centre when the
area is Part armed.
21 - Unarm Fire Coms
Areas assigned to 'Unarm Fire Coms' will respond as follows:
If an assigned area is unarmed and a Fire alarm occurs in
that area, Fire alarm events (for that area) will be reported
to the Alarm Receiving Centre
Areas not assigned to 'Unarm Fire Coms' will never report
Fire alarm events to the Alarm Receiving Centre when the
area is unarmed.
!
Fire alarm events are always reported to the Alarm
Receiving Centre when the area is armed regardless of
whether the area is assigned to this option or not.
22 - Unarm Tamp. Coms
Areas assigned to 'Unarm Tamp. Coms' will respond as follows:
If an assigned area is unarmed and a 24Hr or Tamper
alarm or reportable fault occurs in that area, the event will
be reported to the Alarm Receiving Centre
Areas not assigned to 'Unarm Tamp. Coms' will never report
24Hr or Tamper alarm events or faults to the Alarm Receiving
Centre when the area is unarmed.
!
24Hr and Tamper alarm events are always reported to
the Alarm Receiving Centre when the area is armed
regardless of whether the area is assigned to this
option or not.
23 - Auto Arm Areas
Areas assigned to 'Auto Arm Areas' will respond as follows:
When an assigned area is disarmed, the 'Auto Arm
Delay' timer will start (see page 47 for details)
Every time a detector in that area is activated, the timer is
restarted
If the timer is allowed to expire i.e. no detectors in the
assigned area are activated, the area will arm itself
Areas not assigned to 'Auto Arm Areas' will never try to arm
themselves.
24 - Area A Foyer
Area A can be used as a common area (automatically arms
last and disarms first). Areas assigned to 'Area A Foyer' will
cause the panel to respond as follows:
When all assigned areas are armed, Area A will
automatically arm itself
When any one assigned area is disarmed, Area A will
automatically disarm itself
Areas not assigned to 'Area A Foyer' will not affect the
automatic arming of area A.